A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Organ doses in pediatric patients undergoing cardiac-centered fluoroscopically guided interventions: Comparison of three methods for computational phantom alignment. | LitMetric

Purpose: To assess various computational phantom alignment techniques within Monte Carlo radiation transport models of pediatric fluoroscopically guided cardiac interventional studies.

Methods: Logfiles, including all procedure radiation and machine data, were extracted from a Toshiba infinix-I unit in the University of Florida Pediatric Catheterization Laboratory for a cohort of 10 patients. Two different alignment methods were then tested against a ground truth standard based upon identification of a unique anatomic reference point within images co-registered to specific irradiation events within each procedure. The first alignment method required measurement of the distance from the edge of the exam table to the top of the patient's head (table alignment method). The second alignment method fixed the anatomic reference point to be the geometric center of the heart muscle, as all 10 studies were cardiac in nature. Monte Carlo radiation transport simulations were performed for each patient and intervention using morphometry-matched hybrid computational phantoms for the reference and two tested alignment methods. For each combination, absorbed doses were computed for 28 organs and root mean square organ doses were assessed and compared across the alignment methods.

Results: The percent error in root mean square organ dose ranged from -57% to +41% for the table alignment method, and from -27% to +22% for the heart geometric centroid alignment method. Absorbed doses to specific organs, such as the heart and lungs, demonstrated higher accuracy in the heart geometric centroid alignment method, with average percent errors of 10% and 1.4%, respectively, compared to average percent errors of -32% and 24%, respectively, using the table alignment method.

Conclusions: Of the two phantom alignment methods investigated in this study, the use of an anatomical reference point - in this case the geometric centroid of the heart - provided a reliable method for radiation transport simulations of organ dose in pediatric interventional cardiac studies. This alignment method provides the added benefit of requiring no physician input, making retrospective calculations possible. Moving forward, additional anatomical reference methods can be tested to assess the reliability of anatomical reference points beyond cardiac centered procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6292782PMC
http://dx.doi.org/10.1002/mp.13044DOI Listing

Publication Analysis

Top Keywords

alignment method
28
alignment
14
phantom alignment
12
radiation transport
12
alignment methods
12
reference point
12
table alignment
12
geometric centroid
12
anatomical reference
12
organ doses
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!