The purpose of this study was a dosimetric validation of the Vero4DRT for brain stereotactic radiotherapy (SRT) with extremely small fields calculated by the treatment planning system (TPS) iPlan (Ver.4.5.1; algorithm XVMC). Measured and calculated data (e.g. percentage depth dose [PDD], dose profile, and point dose) were compared for small square fields of 30 × 30, 20 × 20, 10 × 10 and 5 × 5 mm using ionization chambers of 0.01 or 0.04 cm and a diamond detector. Dose verifications were performed using an ionization chamber and radiochromic film (EBT3; the equivalent field sizes used were 8.2, 8.7, 8.9, 9.5, and 12.9 mm) for five brain SRT cases irradiated with dynamic conformal arcs. The PDDs and dose profiles for the measured and calculated data were in good agreement for fields larger than or equal to 10 × 10 mm when an appropriate detector was chosen. The dose differences for point doses in fields of 30 × 30, 20 × 20, 10 × 10 and 5 × 5 mm were +0.48%, +0.56%, -0.52%, and +11.2% respectively. In the dose verifications for the brain SRT plans, the mean dose difference between the calculated and measured doses were -0.35% (range, -0.94% to +0.47%), with the average pass rates for the gamma index under the 3%/2 mm criterion being 96.71%, 93.37%, and 97.58% for coronal, sagittal, and axial planes respectively. The Vero4DRT system provides accurate delivery of radiation dose for small fields larger than or equal to 10 × 10 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2018.05.022DOI Listing

Publication Analysis

Top Keywords

dose
10
extremely small
8
radiation dose
8
brain stereotactic
8
stereotactic radiotherapy
8
vero4drt system
8
small fields
8
measured calculated
8
calculated data
8
fields 30 × 30
8

Similar Publications

Background: Radioactive iodine (RAI) is a common treatment for various thyroid diseases. Previous studies have suggested susceptibility of parathyroid glands to the mutagenic effect of RAI and the development of primary hyperparathyroidism (PHPT). We tested the possible link between prior RAI treatment, disease presentation, and treatment outcomes.

View Article and Find Full Text PDF

This study assesses the effect of carotid sinus blockade applied with a local anesthetic on hemodynamic parameters during carotid endarterectomy (CEA) operations performed under general anesthesia. The medical records of patients who underwent CEA under general anesthesia between January 2020 and December 2022, were retrospectively reviewed. It was recorded whether the patients received carotid sinus block with 2 mL of 2% prilocaine.

View Article and Find Full Text PDF

Purpose: Adaptive radiotherapy accounts for interfractional anatomic changes. We hypothesize that changes in the gross tumor volumes identified during daily scans could be analyzed using delta-radiomics to predict disease progression events. We evaluated whether an auxiliary data set could improve prediction performance.

View Article and Find Full Text PDF

Background: This study investigates the relationship between sagittal abdominal diameter (SAD), a measure of abdominal obesity, and kidney stone disease (KSD) in the U.S. population.

View Article and Find Full Text PDF

Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!