Characterizing Surfaces of Garnet and Steel, and Adsorption of Organic Additives.

Langmuir

BP Institute and Department of Chemistry , University of Cambridge, Cambridge CB3 0EZ , United Kingdom.

Published: July 2018

This work reports that abrasive blasting of a structural steel results in significant retention of garnet abrasive residues. A comparative study of the adsorption behavior of a number of organic species, relevant to paint components and additives, onto the surfaces of garnet and S355 steel from nonaqueous solutions is also presented. Areas per adsorbed molecule, estimated from the isotherm data, suggest a range of molecular orientations on the surfaces. Pronounced differences in the adsorption strength to the garnet and steel were observed, particularly that most additives bind more strongly to steel than to garnet. Surface characterization data from acid-base titrations, photoelectron spectroscopy, and backscattered electron diffraction were used to rationalize the adsorption data obtained. The ramifications of these findings for particular industrial processes, with regards the strength of paint adhesion and paint additive formulations, are highlighted.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.8b01405DOI Listing

Publication Analysis

Top Keywords

surfaces garnet
8
garnet steel
8
garnet
5
steel
5
characterizing surfaces
4
adsorption
4
steel adsorption
4
adsorption organic
4
organic additives
4
additives work
4

Similar Publications

The impact of grinding on particle size, thermal behaviour, and sintering ability of yttrium aluminate glass microspheres with eutectic composition (76.8 mol % AlO and 23.2 mol % YO) was studied.

View Article and Find Full Text PDF

Purpose: To perform vertical bone augmentation on rat parietal bone by coating the inner surface of dense polytetrafluoroethylene (d-PTFE) domes with hydroxyapatite (HA) using Erbium Yttrium Aluminum Garnet (Er:YAG) pulsed laser deposition in a rat model.

Methods: The d-PTFE plate surface, α-tricalcium phosphate (α-TCP) coating, and HA coating were measured using scanning electron microscopy and X-ray diffraction to confirm the replacement of α-TCP with HA via high-pressure steam sterilization. The dome was glued to the center of the rat parietal bone and closed with periosteal and epithelial sutures.

View Article and Find Full Text PDF
Article Synopsis
  • PVDF is a promising material for solid polymer electrolytes because of its good thermal stability and wide electrochemical range, but it faces issues with poor ionic conductivity due to the formation of a harmful alkaline layer on garnet fillers.
  • LiOH on the surface of these fillers contributes to the breakdown of PVDF chains, leading to unwanted chemical bonds; this can be mitigated by treating the fillers with acetic acid to create alkali-free garnets.
  • The modified PVDF electrolyte shows significantly improved ionic conductivity and a wider electrochemical window, resulting in better performance for solid-state lithium batteries, evidenced by higher discharge capacity and cycle stability.
View Article and Find Full Text PDF

Successful Multi-Modal Laser Intervention and Histopathological Evaluation of Multiple Glomangiomas.

Lasers Surg Med

December 2024

Department of Dermatology, Veterans Health Administration, San Antonio, Texas, USA.

Objectives: Glomangiomas are benign vascular malformations that exist within the spectrum of glomuvenous malformations which consist of varying amounts of glomus cells, vascular spaces, and smooth muscle. Glomangiomas are often treated due to associated pain, particularly when located on pressure areas such as the back or extensor surfaces, which can cause difficulty with certain activities and occupational functions. Histologically glomangiomas consist of prominent dilated vascular spaces lined by glomus cells typically situated in the deep-dermis to subcutaneous fat which limits treatment to modalities capable of reaching the depth of the tumor including excision, sclerotherapy, and laser therapy.

View Article and Find Full Text PDF

Background and objective Applying different hygiene tools for implant maintenance alters surface configurations, impacting bacterial adhesion on titanium implant surfaces and potentially leading to peri-implant diseases. This study aimed to assess the alterations in surface topography of titanium implant fixtures after utilizing hygiene instruments such as airflow; erbium, chromium-doped: yttrium, scandium, gallium, and garnet (Er, Cr: YSGG) laser; and titanium brush, under scanning electron microscope (SEM) observation. Materials and methods We employed an experimental laboratory study design for this research, involving 20 MegaGen ST titanium implant fixtures (MegaGen Implant Co.

View Article and Find Full Text PDF