Background: The role of false lumen patency related to aortic growth, re-interventions, and post-discharge mortality in the chronic phase of repaired type A acute aortic dissection (TAAAD) remains controversial. We investigated the role of postoperative false lumen patency during long-term follow-up.
Methods: Based on postoperative CT images of 70 candidates, 58 eligible patients without alteration of false lumen status were assigned into three groups: complete patency, partial patency, and complete thrombosis. Aortic growth of 7 levels was analyzed.
Results: Persistent complete patency in post-operative TAAAD presents faster expansion of aortic diameter (95% CI, 0.35 to 11.52; P=0.038; B=5.935) and more patients with growth rate>5mm/year (P=0.029). The persistent status of false lumen does not predict post-discharge mortality (P=0.479). History of coronary artery disease (CAD) is the only independent predictor of post-discharge mortality.
Conclusions: In TAAAD patients without change of postoperative false lumen status, completely patent false lumen presents faster aortic growth and more patients with growth rate>5mm/year. False lumen status does not correlate with late survival. Here we provide an insight into persistent postoperative false lumen in TAAAD patients and may help cast light on aortic dissection in this specific subgroup to improve their late outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2018.01.010 | DOI Listing |
Sci Rep
January 2025
Department of Cardiovascular Surgery, Nihon University Hospital, Itabashi-ku, Tokyo, Japan.
We investigated the influence of false lumen (FL) status on the systemic inflammatory response triggered by acute aortic dissection (AAD) using cytokine profiling. The study included 44 patients with AAD. Patients were divided between those with a thrombosed FL (Group T, n = 21) and those with a non-thrombosed FL (Group P, n = 23).
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
December 2024
Department of Cardiovascular Surgery, West China Hospital of Sichuan University, P.R. China. Electronic address:
In surgery for acute type A aortic dissection, controlling bleeding from the posterior wall of the proximal anastomosis is particularly challenging. To address this, we use the "reversed turn-up technique." For the reinforcement of the proximal aortic stump, Teflon felt strips were placed inside and outside the suture line with 4-0 polypropylene continuous transverse mattress sutures, and BioGlue was applied to the false lumen.
View Article and Find Full Text PDFMed Phys
December 2024
Department of Echocardiography, Ultrasound Diagnostic Center, The First Hospital of Jilin University, Changchun, China.
Background: Dialysis Access (DA) stenosis impacts hemodialysis efficiency and patient health, necessitating exams for early lesion detection. Ultrasound is widely used due to its non-invasive, cost-effective nature. Assessing all patients in large hemodialysis facilities strains resources and relies on operator expertise.
View Article and Find Full Text PDFVasc Endovascular Surg
December 2024
Baylor Scott and White Heart and Vascular Hospital, Dallas, TX, USA.
: Contemporary treatments of acute aortic dissection, including medical, surgical, and endovascular options, are remarkably effective at the management of malperfusion and rupture. Unfortunately, long-term studies indicate that 30%-50% of patients need secondary procedures to treat progressive aneurysmal enlargement of the untreated aorta. The Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique was introduced to improve long-term outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!