Fructokinase from beef liver showed a clear reversal in specificity when the two isomers of ATP beta S were used as substrates with Mg2+ and Cd2+, with the Sp isomer having the higher V/K value with Mg2+ and the Rp isomer the higher value with Cd2+. The delta isomer of MgATP is thus the active form of the substrate. The substitution of sulfur for oxygen in the noncoordinated position of the beta-phosphate caused a 102-fold decrease in V/K over the value seen with MgATP, while substitution in the coordinated position gave a 21-fold decrease over the V/K value seen with CdATP. The Km values were little affected by sulfur substitution, showing that the wrong screw sense isomers were nonproductively bound almost as well as the correct ones. When ADP alpha S was used as a substrate in the reverse reaction, the Sp isomer showed the highest V/K value with both Mg2+ and Cd2+, suggesting that the metal ion is not coordinated to the alpha-phosphate during transphosphorylation. The failure of CrATP to act as a substrate for fructokinase suggests that the enzyme inserts one of its side chains into the inner coordination sphere of the metal ion during the reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1021/bi00328a008DOI Listing

Publication Analysis

Top Keywords

screw sense
8
mg2+ cd2+
8
isomer higher
8
v/k mg2+
8
decrease v/k
8
metal ion
8
determination screw
4
sense specificity
4
specificity bovine
4
bovine liver
4

Similar Publications

Objectives: Gastrointestinal (GI) disturbance is a frequent complication in patients with thoracolumbar vertebral fracture (TVF). Transcutaneous electrical acustimulation (TEA) has been reported to effectively accelerate postoperative GI function recovery after abdominal surgery. This study aimed to investigate the effects of TEA on postoperative recovery and the associated mechanisms.

View Article and Find Full Text PDF

Filtering facepiece respirators (FFRs) are manufactured in discrete sizes, with some models being limited in relation to accommodating the fit of some sex and race combinations. This study presents the development of a custom-fit respiratory protective device (RPD) which conforms to a user's facial features and flexes and moves with facial movements during use. Our design also integrates a pressure-sensing network, which continuously monitors fit and will alert the user when the fit is compromised.

View Article and Find Full Text PDF

Guided Bone Regeneration in the Posterior Mandible Using a Resorbable Metal Magnesium Membrane and Fixation Screws: A Case Report.

Case Rep Dent

December 2024

Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorder, Charité-Universitätsmedizin Berlin, Aßmannshauser Straße 4-6 14197, Berlin, Germany.

Due to bone loss, implant placement in the posterior mandible is often impossible without prior augentative procedures. The reconstruction of bone defects with horizontal and vertical components using particulated bone grafts requires the placement of a mechanically stable structure for stabilization of the grafting material. Although titanium-reinforced membranes and titanium meshes have been shown to be effective in this indication, the necessity of their removal, often in a separate surgical procedure, is seen as a disadvantage.

View Article and Find Full Text PDF

A handheld fiber-optic tissue sensing device for spine surgery.

PLoS One

December 2024

Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands.

The demographic shift has increased the demand for surgical interventions to address age-related degenerative diseases, such as spinal fusion. Accurate placement of pedicle screws, crucial for successful spinal fusion, varies widely with physician experience. Integrating tissue sensing into spine surgical instruments allows intraoperative examination of tissue properties, providing surgeons with additional information to prevent screw misplacement.

View Article and Find Full Text PDF

Background: Pectus excavatum is the most frequent congenital defect of the chest wall. Surgical treatment with modified Ravitch-type repair is recommended in patients with cosmetic dissatisfaction or considerable cardiopulmonary symptoms. We aimed to analyze the surgical, aesthetic, cardiopulmonary functions and patient satisfaction outcomes of modified Ravitch repair pre and postoperatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!