Medical device biocompatibility testing is used to evaluate the risk of adverse effects on tissues from exposure to leachates/extracts. A battery of tests is typically recommended in accordance with regulatory standards to determine if the device is biocompatible. In vitro cytotoxicity, a key element of the standards, is a required endpoint for all types of medical devices. Each validated cytotoxicity method has different methodology and acceptance criteria that could influence the selection of a specific test. In addition, some guidances are more specific than others as to the recommended test methods. For example, the International Organization for Standardization (ISO) cites preference for quantitative methods (e.g., tetrazolium (MTT/XTT), neutral red (NR), or colony formation assays (CFA)) over qualitative methods (e.g., elution, agar overlay/diffusion, or direct), while a recent ISO standard for contact lens/lens care solutions specifically requires a qualitative direct test. Qualitative methods are described in United States Pharmacopeia (USP) while quantitative CFAs are listed in Japan guidance. The aim of this review is to compare the methodologies such as test article preparation, test conditions, and criteria for six cytotoxicity methods recommended in regulatory standards in order to inform decisions on which method(s) to select during the medical device safety evaluation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.yrtph.2018.06.003 | DOI Listing |
Sci Prog
January 2025
School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Purpose: The aim of this study was to evaluate the efficacy and safety of the Ahmed glaucoma valve in pediatric patients with refractory glaucoma.
Methods: A comprehensive literature search was conducted across multiple major databases, including PubMed, Embase, the Cochrane Library of Systematic Reviews, Science Direct, China's National Knowledge Infrastructure, and the Wanfang database. We retrieved studies published before December 2022 that met the inclusion criteria, including clinical controlled trials (randomized controlled trials) and clinical noncontrolled trials (non-randomized controlled trials) on the use of Ahmed glaucoma valve in pediatric patients with refractory glaucoma.
Sci Prog
January 2025
National Fire Research Institute, Asan-si, Republic of Korea.
Firefighters are exposed to the risk of burns at fire scenes. In 2020, the National Fire Agency of the Republic of Korea surveyed 50,527 firefighters and identified 242 burn-related incidents. The body parts affected by these burns were the hands (28.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
January 2025
The Permanente Medical Group, Oakland, CA.
Study Design: A retrospective cohort study.
Objective: To determine if there is a difference in reoperations for adjacent segment disease (operative ASD) and nonunion (operative nonunion) in lumbar fusions that stop at T10/T11/T12 versus L1.
Summary Of Background Data: Current lumbar spine surgery is based on the belief that ASD occurs if fusions are stopped at L1 although there is varying evidence to support this assumption.
Front Surg
January 2025
Department of Cardiovascular Medicine, The Second Xiangya Hospital, Central South University, Changsha, Hunan, China.
We report a case of a patient with dilated cardiomyopathy who experienced recurrent ventricular tachycardia (VT) and multiple defibrillations following CRT-D implantation. Due to worsening cardiac function, the patient required surgical implantation of a left ventricular assist device (LVAD) as a bridge to heart transplantation. During the procedure, we used the Ensite three-dimensional mapping system to perform activation and substrate mapping of the VT targets, followed by endocardial and epicardial cryoballoon ablation of clinical VT.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Division of Cardiovascular Medicine, Department of Medicine, China Medical University Hospital, China Medical University, Taichung 404327, Taiwan.
Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.
Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.