Evaluation of the Rapid Polymyxin NP test for detection of colistin susceptibility in Enterobacteriaceae isolated from Thai patients.

Diagn Microbiol Infect Dis

Division of Infectious Diseases and Tropical Medicine, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Electronic address:

Published: October 2018

Development and evaluations of the Rapid Polymyxin NP test for detection of colistin resistance in Enterobacteriaceae have been recently reported. In this study, we evaluated the performance of the test using a larger number of Enterobacteriaceae, and a larger proportion of isolates with a colistin MIC close to the breakpoint. Out of 339 isolates, the Rapid Polymyxin NP test detected colistin resistance in 13 isolates of Escherichia coli, 213 isolates of Klebsiella pneumoniae, 9 isolates of Enterobacter aerogenes, and 10 isolates of the other Enterobacteriaceae species. Sensitivity and specificity of the test for detecting colistin resistance were 100% and 95.9%, respectively. Positive predictive value and negative predictive value were 98.3% and 100%, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2018.05.009DOI Listing

Publication Analysis

Top Keywords

rapid polymyxin
12
polymyxin test
12
colistin resistance
12
test detection
8
detection colistin
8
isolates
6
test
5
colistin
5
evaluation rapid
4
colistin susceptibility
4

Similar Publications

Pathogenic bacteria are the source of many serious health problems, such as foodborne diseases and hospital infections. Timely and accurate detection of these pathogens is of vital significance for disease prevention, control of epidemic spread, and protection of public health security. Rapid identification of pathogenic bacteria has become a research focus in recent years.

View Article and Find Full Text PDF

A multi-branched fluorogenic probe for the rapid and specific detection of Gram-negative bacteria is reported. Three Gram-negative-targeting azido-modified polymyxins were clicked onto a trivalent scaffold functionalised with the environmental green-emitting fluorophore 7-nitrobenz-2-oxa-1,3-diazole. The probe allowed wash-free detection of target bacteria with increased sensitivity and lower limits of detection compared to monovalent probes.

View Article and Find Full Text PDF

Tailored multilayer nanoparticles against resistant P. aeruginosa by disrupting the thickened mucus, dense biofilm and hyperinflammation.

J Control Release

December 2024

School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China; State Key Laboratory of Anti-Infective Drug Discovery and Development, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China; Guangdong Provincial Key Laboratory of Chiral Molecule and Drug Discovery, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China. Electronic address:

Therapeutic challenges of chronic pulmonary infections caused by multidrug-resistant Pseudomonas aeruginosa (MDRP. aeruginosa) biofilms due to significantly enhanced antibiotic resistance. This resistance is driven by reduced outer membrane permeability, biofilm barriers, and excessive secretion of virulence factors.

View Article and Find Full Text PDF

Background: The bacterium Vibrio cholerae causes diarrheal illness and can acquire genetic material leading to multiple drug resistance (MDR). Rapid detection of resistance-conferring mobile genetic elements helps avoid the prescription of ineffective antibiotics for specific strains. Colorimetric loop-mediated isothermal amplification (LAMP) assays provide a rapid and cost-effective means for detection at point-of-care since they do not require specialized equipment, require limited expertise to perform, and can take less than 30 min to perform in resource limited regions.

View Article and Find Full Text PDF

Colistin is essential for treating multidrug-resistant Gram-negative bacterial infections but has significant nephrotoxic side effects. Traditional approaches for studying colistin's nephrotoxicity are challenged by the rapid metabolism of its prodrug, colistin methanesulfonate and the difficulty of obtaining adequate plasma from critically ill patients. To address these challenges, we developed the Spheroid Nephrotoxicity Assessing Platform (SNAP), a microfluidic device that efficiently detects colistin-induced toxicity in renal proximal tubular epithelial cell (RPTEC) spheroids within 48 hours using just 200 μL of patient plasma.