Purpose: External loading of osteoarthritic and healthy knees correlates with current and future osteochondral tissue state. These relationships have not been examined following anterior cruciate ligament reconstruction. We hypothesised greater magnitude tibiofemoral contact forces were related to increased prevalence of osteochondral pathologies, and these relationships were exacerbated by concomitant meniscal injury.

Methods: This was a cross-sectional study of 100 individuals (29.7 ± 6.5 years, 78.1 ± 14.4 kg) examined 2-3 years following hamstring tendon anterior cruciate ligament reconstruction. Thirty-eight participants had concurrent meniscal pathology (30.6 ± 6.6 years, 83.3 ± 14.3 kg), which included treated and untreated meniscal injury, and 62 participants (29.8 ± 6.4 years, 74.9 ± 13.3 kg) were free of meniscal pathology. Magnetic resonance imaging of reconstructed knees was used to assess prevalence of tibiofemoral osteochondral pathologies (i.e., cartilage defects and bone marrow lesions). A calibrated electromyogram-driven neuromusculoskeletal model was used to predict medial and lateral tibiofemoral compartment contact forces from gait analysis data. Relationships between contact forces and osteochondral pathology prevalence were assessed using logistic regression models.

Results: In patients with reconstructed knees free from meniscal pathology, greater medial contact forces were related to reduced prevalence of medial cartilage defects (odds ratio (OR) = 0.7, Wald χ(2) = 7.9, 95% confidence interval (CI) = 0.50-95, p = 0.02) and medial bone marrow lesions (OR = 0.8, Wald χ(2) = 4.2, 95% CI = 0.7-0.99, p = 0.04). No significant relationships were found in lateral compartments. In reconstructed knees with concurrent meniscal pathology, no relationships were found between contact forces and osteochondral pathologies.

Conclusions: In patients with reconstructed knees free from meniscal pathology, increased contact forces were associated with fewer cartilage defects and bone marrow lesions in medial, but not, lateral tibiofemoral compartments. No significant relationships were found between contact forces and osteochondral pathologies in reconstructed knees with meniscal pathology for any tibiofemoral compartment. Future studies should focus on determining longitudinal effects of contact forces and changes in osteochondral pathologies.

Level Of Evidence: IV.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-018-5006-3DOI Listing

Publication Analysis

Top Keywords

contact forces
36
meniscal pathology
24
reconstructed knees
20
osteochondral pathologies
16
anterior cruciate
12
cruciate ligament
12
ligament reconstruction
12
free meniscal
12
cartilage defects
12
marrow lesions
12

Similar Publications

Self-organized contact line instabilities (CLI) of a macroscopic liquid crystal (LC) droplet can be an ingenious pathway to generate a large collection of miniaturized LC drops. For example, when a larger drop of volatile solvent (e.g.

View Article and Find Full Text PDF

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

In the title compound, CHFO, a central -hybridized carbon atom is decorated with three hepta-fluoro-2-meth-yloxy(cyclo-pent-1-ene) arms and a methyl group. The primary packing is determined by C-F⋯F-C inter-actions, forming [001] chains, which are consolidated weaker C-F⋯F-C and C-H⋯F-C contacts. A Hirshfeld surface analysis was conducted to aid in the visualization of these various influences on the packing: this revealed that the largest contribution to the surface contacts arises from F⋯F inter-actions (53.

View Article and Find Full Text PDF

Achieving atomic-level characterization of the diamond (001) surface has been a persistent goal over recent decades. This pursuit aims to understand the smooth growth of diamonds and investigate surface defects and adsorbates relevant to applications. However, the inherently low conductivity and the short C-C bonds present significant challenges for atomic resolution imaging.

View Article and Find Full Text PDF

Robotic devices with integrated tactile sensors can accurately perceive the contact force, pressure, sliding, and other tactile information, and they have been widely used in various fields, including human-robot interaction, dexterous manipulation, and object recognition. To address the challenges associated with the initial value drift, and to improve the durability and accuracy of the tactile detection for a robotic dexterous hand, in this study, a flexible tactile sensor is designed with high repeatability by introducing a supporting layer for pre-separation. The proposed tactile sensor has a detection range of 0-5 N with a resolution of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!