One-hundred and three patients with intertrochanteric hip fractures as classified by the OTA 2007 system underwent fixation using the telescoping AOS Galileo lag screw system and ES Nail (a long IM nail). Thirty-one patients (76%) were female and ten (24%) were male, with an average age of 75.70 ± 11.3 years at date of surgery. At final follow-up 21 (53%) patients returned to their pre-fracture ambulatory status, 20 (47%) had a reduction in ambulatory status, and no patients were confined to a wheel chair. The telescoping capability of the AOS Galileo lag screw allowed for a decrease in total length by 3.96 ± 3.04 mm during fracture healing. The TAD distance at final follow-up was 14.09 ± 4.69 mm. Lateral protrusion of the lag screw into soft tissue did not occur. There was one reported incidence of femoral head cutout, which occurred after the lag screw had telescoped its entire distance and began functioning as a rigid non-compressible lag screw. All other fractures healed uneventfully and no device failure occurred. The AOS Galileo telescoping lag screw has shown promise concerning IT fracture fixation and will continue to undergo further investigation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990323 | PMC |
http://dx.doi.org/10.1016/j.jor.2018.05.034 | DOI Listing |
Objectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).
Methods: Design: Retrospective chart review.
Setting: Single academic, Level-1 Trauma Center.
Cureus
December 2024
Department of Surgery, Florida Atlantic University Charles E. Schmidt College of Medicine, Boca Raton, USA.
Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.
View Article and Find Full Text PDFOrthop Surg
January 2025
Department of Orthopaedic and Traumatology, Trabzon Kanuni Training and Research Hospital, Trabzon, Turkey.
Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.
Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM).
PLoS One
January 2025
Çukurova University Faculty of Medicine, Department of Orthopedics and Traumatology, Adana, Türkiye.
Background: This study aimed to analyze the files of patients treated using PFN-A or INTERTAN intramedullary nails to reveal additional superiorities or disadvantageous factors for selecting the better intramedullary fixation method in patients presenting with intertrochanteric femur fractures.
Methods: In this retrospective study, the files of the patients who were operated on for intertrochanteric femur fractures using intramedullary fixation methods between September 2010 and June 2015 in the Orthopedics and Traumatology Clinic, Çukurova University Faculty of Medicine, were reviewed. The data including age, gender, chronic diseases, causes of fractures, fracture classification based on Arbeitsgemeinschaft für Osteosynthesefragen (AO), the nail type (long or short), the interval between trauma and surgery, duration of anesthesia and surgery, hospitalization duration, amount of blood transfusion, the Tip-Apex Distance (TAD) in postoperative radiographs, functional outcomes according to Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), postoperative complications, need for revision, and mortality was noted.
Ann Plast Surg
December 2024
Department of Orthopaedic Surgery, Duson Hospital, Ansan, Korea.
Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!