AI Article Synopsis

  • The study explores the use of parallel imaging compressed sensing (PICS) in MRI to decrease scan time and enhance signal-to-noise ratio (SNR) during prostate brachytherapy dosimetry.
  • Ten patients undergoing treatment were scanned using advanced MRI techniques, and images were reconstructed with varying acceleration factors to assess image quality.
  • Results showed that PICS allowed for sufficient image quality at acceleration factors up to 4, maintaining SNR and anatomical detail, suggesting it can reduce scan time while improving dosimetry efficiency without requiring additional equipment like an endorectal coil.

Article Abstract

Purpose: To investigate the feasibility of using parallel imaging compressed sensing (PICS) to reduce scan time and improve signal-to-noise ratio (SNR) in MRI-based postimplant dosimetry of prostate brachytherapy.

Methods And Materials: Ten patients underwent low-dose-rate prostate brachytherapy with radioactive seeds stranded with positive magnetic resonance-signal seed markers and were scanned on a Siemens 1.5T Aera. MRI comprised a fully balanced steady-state free precession sequence with two 18-channel external pelvic array coils with and without a rigid two-channel endorectal coil. The fully sampled data sets were retrospectively subsampled with increasing acceleration factors and reconstructed with parallel imaging and compressed sensing algorithms. The images were assessed in a blinded reader study by board-certified care providers. Rating scores were compared for statistically significant differences between reconstruction types.

Results: Images reconstructed from subsampling up to an acceleration factor of 4 with PICS demonstrated consistently sufficient quality for dosimetry with no apparent loss of SNR, anatomy depiction, or seed/marker conspicuity when compared to the fully sampled images. Images obtained with acceleration factors of 5 or 6 revealed reduced spatial resolution and seed marker contrast. Nevertheless, the reader study revealed that images obtained with an acceleration factor of up to 5 and reconstructed with PICS were adequate-to-good for postimplant dosimetry.

Conclusions: Combined parallel imaging and compressed sensing can substantially reduce scan time in fully balanced steady-state free precession imaging of the prostate while maintaining adequate-to-good image quality for postimplant dosimetry. The saved scan time can be used for multiple signal averages and improved SNR, potentially obviating the need for an endorectal coil in MRI-based postimplant dosimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brachy.2018.05.003DOI Listing

Publication Analysis

Top Keywords

parallel imaging
16
imaging compressed
16
compressed sensing
16
postimplant dosimetry
16
mri-based postimplant
12
scan time
12
signal-to-noise ratio
8
dosimetry prostate
8
prostate brachytherapy
8
reduce scan
8

Similar Publications

Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.

Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.

View Article and Find Full Text PDF

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Background: Thymic epithelial tumors (TETs), including thymoma and thymic carcinoma, are rare thoracic tumors of the anterior mediastinum. For those with advanced disease, platinum-based chemotherapy is used as first-line treatment. However, there is no standard regimen established for TET at progression after initial therapy, and treatment options for advanced/recurrent TETs are limited.

View Article and Find Full Text PDF

PFSH-Net: Parallel frequency-spatial hybrid network for segmentation of kidney stones in pre-contrast computed tomography images of dogs.

Comput Biol Med

January 2025

Division of Electronics and Information Engineering, College of Engineering, Jeonbuk National University, 567, Baekje-daero, Deokjin-gu, 54896, Jeonju, Republic of Korea. Electronic address:

Kidney stone is a common urological disease in dogs and can lead to serious complications such as pyelonephritis and kidney failure. However, manual diagnosis involves a lot of burdens on radiologists and may cause human errors due to fatigue. Automated methods using deep learning models have been explored to overcome this limitation.

View Article and Find Full Text PDF

Background: Despite amyloid-β (Aβ) plaques and tau neurofibrillary tangles being recognized as major Alzheimer's Disease (AD) hallmarks, their synergistic contribution to neuronal activity remains unclear. We developed a neuroimaging-based personalized brain activity model to assess the in-vivo functional impact of AD pathophysiology. In previous reports, model-inferred neuronal excitability predicted disease progression (i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?