AI Article Synopsis

  • A study was conducted to compare the safety and effectiveness of two imaging techniques (intracardiac echocardiography (ICE) vs. transesophageal echocardiography (TEE)) for guiding left atrial appendage occlusion (LAAO) procedures using specific devices in Italy.
  • Data from 604 LAAO procedures showed high success rates for both techniques (around 94%), with slightly lower complication rates for ICE compared to TEE (4.2% vs. 6.5%).
  • The findings suggest that ICE could be a viable alternative to TEE for LAAO, pending further experience and training with the technique.

Article Abstract

Objectives: This study sought to evaluate the feasibility, safety, and efficacy of intracardiac echocardiography (ICE)-guided versus transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) by the use of Amplatzer Cardiac Plug or Amulet devices included in a large Italian registry.

Background: TEE is widely used for LAAO procedure guidance. ICE may be a potential alternative imaging modality in LAAO.

Methods: Data from 604 LAAO procedures performed in 16 Italian centers were reviewed. ICE-guided LAAO was performed in 187 patients, whereas TEE was used in 417 patients. Procedural success was defined as LAAO without occurrence of pericardial tamponade, stroke, systemic embolism with end organ damage, major bleeding, and device embolization. Stroke, transient ischemic attack, major bleeding, overall and cardiovascular death were analyzed.

Results: CHADS-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65 to 74 years, sex category) and HAS-BLED (hypertension, abnormal renal and liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores were similar between the ICE and TEE groups. TEE implied lower procedural (delta 12 min) and fluoroscopy time (delta 5 min) when compared with ICE. Procedural success was similarly high (≥94%) between the TEE and ICE groups with a complication rate of 6.5% for TEE versus 4.2% for ICE (odds ratio: 1.468; 95% confidence interval: 0.681 to 3.166; p = 0.327). At median follow-up of 451 days (interquartile range: 162 to 899 days), the rate of cerebral ischemic events was similar between TEE-guided and ICE-guided procedures.

Conclusions: ICE-guided LAAO by means of Amplatzer devices may represent a second alternative imaging modality after an appropriate learning curve and bearing in mind that pre-procedural computed tomography imaging is mandatory. When comparing ICE with TEE, TEE remains the gold standard.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2018.05.008DOI Listing

Publication Analysis

Top Keywords

versus transesophageal
8
alternative imaging
8
ice-guided laao
8
procedural success
8
major bleeding
8
stroke transient
8
transient ischemic
8
ischemic attack
8
ice tee
8
delta min
8

Similar Publications

In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO versus a direct CO blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity.

View Article and Find Full Text PDF
Article Synopsis
  • * It analyzes 220 patients, revealing that a greater change in mitral valve annulus area after surgery is linked to a higher risk of FMS, with 6.4% of patients developing this condition.
  • * The research identifies a 56.2% threshold in the change ratio of mitral valve annulus area as a key predictor for FMS, suggesting preoperative measurements can help optimize surgical outcomes.
View Article and Find Full Text PDF

Background: The transesophageal echocardiogram (TEE) is the standard imaging modality for confirming the presence or absence of patent foramen ovale. PFO is a flap valve depending on the pressure change between the left and right atrium, which can help determine whether to open. 3D-TEE was shown to optimize the visualization of PFO.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the link between a right atrial septal microthrombus and stroke in patients with a patent foramen ovale (PFO), identifying a possible pathway for stroke risk.
  • Out of 466 patients examined, 34 (7%) had a detected microthrombus, with a higher incidence of strokes in this group compared to those without.
  • The findings suggest that PFO is a significant risk factor for microthrombus formation, highlighting its importance for managing stroke risk in patients with PFO.
View Article and Find Full Text PDF
Article Synopsis
  • Transthoracic echocardiography (TTE) is an effective, non-invasive alternative to transesophageal echocardiography (TEE) for guiding the repair of atrial and ventricular septal defects.
  • A study involving 1295 patients found that TTE had similar procedural success rates and residual shunt outcomes as TEE.
  • However, TTE resulted in fewer late complications and shorter procedure and fluoroscopy times, making it a potentially more favorable option.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!