Background: Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care.

Methods: Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores.

Results: The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections.

Conclusion: This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991694PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0198595PLOS

Publication Analysis

Top Keywords

poc test
12
criteria
11
criteria required
8
tract infections
8
point care
8
uti test
8
healthcare professionals
8
comments provided
8
remaining criteria
8
test detect
8

Similar Publications

To provide proof-of-concept (PoC), dose-range finding, and safety data for BI 1358894, a TRPC4/5 ion channel inhibitor, in patients with borderline personality disorder (BPD). This was a phase 2, multinational, randomized, double-blind, placebo controlled trial. Patients were randomized to oral placebo or BI 1358894 (5 mg, 25 mg, 75 mg, or 125 mg) once daily in a 2.

View Article and Find Full Text PDF

Background: High blood pressure is a prevalent condition in patients with chronic kidney disease on hemodialysis. Adequate control of high blood pressure is essential to reducing deaths in this group. The present study aimed to observe mortality prospectively in a group of patients in hemodialysis and hemodiafiltration programs in whom the use of antihypertensives was optimized with the point-of-care dry weight (POC-DW) technique.

View Article and Find Full Text PDF

Patient-centred newer testing methods for major cardiac disorders.

Indian J Thorac Cardiovasc Surg

February 2025

CTVS Department, AIIMS Rishikesh, Rishikesh, 249203 India.

Unlabelled: Testing methods of detecting various cardiac biomarkers play a significant influence in determining and treating cardiac-related conditions and ultimate prognosis. With the increasing global prevalence of cardiac disease, the importance of rapid testing methods in diagnosis and management has grown tremendously. The point-of-care testing (POCT) method is a potential biochemical diagnostic technique that may overcome the issue of delayed laboratory results, particularly in regions with limited access to advanced laboratory equipment or resource-constrained.

View Article and Find Full Text PDF

In recent years, the increasing prevalence of viral infections such as dengue (DENV) and chikungunya (CHIKV) has emphasized the vital need for new diagnostic techniques that are not only quick and inexpensive but also suitable for point-of-care and home usage. Existing diagnostic procedures, while useful, sometimes have limits in terms of speed, mobility, and price, particularly in resource-constrained environments and during epidemics. To address these issues, this study proposes a novel technique that combines 3D printing technology with electrochemical biosensors to provide a highly sensitive, user-friendly, and customizable diagnostic platform.

View Article and Find Full Text PDF

Diagnostic Accuracy of a Point-Of-Care aMMP-8 Test for Discriminating Periodontal Health Status in Adults: Validation Trials and Updated Meta-Analysis.

J Clin Periodontol

January 2025

Perio-Implant Innovation Center, Institute for Integrated Oral, Craniofacial and Sensory Research and Department of Oral and Maxillofacial Implantology and National Clinical Research Center of Stomatology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Aim: To evaluate the diagnostic accuracy of an active matrix metalloproteinase-8 (aMMP-8) point-of-care oral rinse test (POC-ORT) for predicting periodontitis in treatment-naïve subjects in two independent studies and update a recent meta-analysis.

Methods: The aMMP-8 POC-ORT index test was performed in a representative population in Hong Kong, China, and a consecutive convenience sample in Shanghai, China. The reference standard was the 2017 World Workshop classification of periodontal diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!