Importance: A simple, reliable tool for rapid estimation of weight in children would be useful in limited-resource settings where current weight estimation tools are not reliable, nearly all global under-five mortality occurs, severe acute malnutrition is a significant contributor in approximately one-third of under-five mortality, and a weight scale may not be immediately available to healthcare professionals including first-response providers.
Objective: To test the accuracy and precision of an existing weight estimation tool based on patient height and mid-upper arm circumference (MUAC) in children between six months and five years of age in low-to-middle income countries.
Design: Data were collected in 2,434 nutritional surveys during 1992-2017 using a modified Expanded Program of Immunization two-stage cluster design.
Setting: Locations in 51 low-to-middle income countries with high prevalence of acute and chronic malnutrition.
Participants: Of 1,848,979 children enrolled in the surveys, a total of 1,800,322 children met inclusion criteria (age 6-59 months; weight ≤ 25 kg; MUAC 80-200 mm) and exclusion criterion (bilateral pitting edema and biologically implausible measurements based on WHO flagging criteria).
Exposures: Weight was estimated by a regression procedure using database height and MUAC.
Main Outcomes And Measures: Mean percentage difference between true and estimated weight (MPD), proportion of estimates accurate to within ± 10% and ± 20% of true weight (PW10 and PW20), weighted Kappa statistic, and Bland-Altman bias (bias) were reported as measures of tool accuracy. Standard deviation (SD) of the MPD and Bland-Altman 95% limits of agreement (LOA) were reported as measures of tool precision.
Results: The height model fitted for MUAC classes was accurate and precise. MPD was +0.67% (SD = 9.95%); PW10/PW20 were 68.31% (95% CI 68.24%, 68.38%)/94.73% (95% CI 94.69%, 94.76%); and bias (LOA) were +0.06 kg (-1.97 kg; +2.10 kg). For MUAC < 115 mm, PW10/PW20 were 63.91% (95% CI 63.42%, 64.40%)/90.72% (95% CI 90.42%, 91.01%); and bias (LOA) were +0.14 kg (-1.29 kg; +1.56 kg). For 115 mm ≤ MUAC < 125 mm, PW10/PW20 were 76.27% (95% CI 76.03%, 76.51%)/96.36% (95% CI 96.25%, 96.46%); and bias (LOA) were +0.06 kg (-1.20 kg; +1.33 kg). For MUAC > 125 mm, PW10/PW20 were 69.93% (95% CI 69.86%, 70.00%)/95.27% (95% CI 95.24%, 95.30%); and bias (LOA) were +0.05 kg (-2.04 kg; +2.13 kg).
Conclusions And Relevance: An updated model estimating weight from height and MUAC in a large database of children aged 6 to 59 months across a wide range of low-to-middle income countries with high prevalence of acute and chronic malnutrition was confirmed to be accurate and precise. A height-based weight estimation tape stratified according to MUAC classes is proposed for children aged 6-59 months in limited-resource settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991734 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0197769 | PLOS |
H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Nursing, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia.
Background: Traditional childhood uvulectomy (TCU) is an unregulated cultural practice associated with significant health risks, including infections, anemia, aspiration, and oral or pharyngeal injuries. The reuse of unsafe tools such as blades, needles, or thread loops exacerbates the spread of infectious diseases like HIV and hepatitis B. Despite its clinical significance, the pooled prevalence and associated factors of TCU have not been adequately examined through systematic reviews or meta-analyses.
View Article and Find Full Text PDFJAMA Netw Open
January 2025
Department of Neurology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
Importance: The net clinical effect of early vs later direct oral anticoagulant (DOAC) initiation after atrial fibrillation-associated ischemic stroke is unclear.
Objective: To investigate whether early DOAC treatment is associated with a net clinical benefit (NCB).
Design, Setting, And Participants: This was a post hoc analysis of the Early Versus Late Initiation of Direct Oral Anticoagulants in Post-Ischaemic Stroke Patients With Atrial Fibrillation (ELAN) open-label randomized clinical trial conducted across 103 sites in 15 countries in Europe, the Middle East, and Asia between November 6, 2017, and September 12, 2022, with a 90-day follow-up.
Trop Anim Health Prod
January 2025
Livestock Farm Complex, Veterinary College and Research Institute, TANUVAS, Salem, 636 001, India.
In this study, data on pedigree, production traits for 19 years (2002-2022) of Salem Black goat from the Mecheri Sheep Research Station, Tamil Nadu, India was used. Various growth traits viz., birth weight (BW), weaning weight (WW), 6-month weight (6W), 9-month weight (9W), 12-month weight (YW), pre- and post-weaning average daily gain (ADG) (3-6, 6-9, 9-12 and 3-12 months) were analyzed.
View Article and Find Full Text PDFTrop Anim Health Prod
January 2025
Department of Biotechnology, Yeungnam University, Gyeongsan, Gyeongbuk, 38541, Republic of Korea.
To improve the quality and yield of the Korean beef industry, selection criteria often focus on estimated breeding values for carcass weight (CWT), eye muscle area (EMA), backfat thickness (BF), and marbling score (MS). This study estimated genetic parameters and assessed the accuracy of genomic estimated breeding values (GEBVs) using SNP weighting methods. We compared the accuracy of these methods with the genomic best linear unbiased prediction (GBLUP) and various Bayesian approaches (BayesA, BayesB, BayesC, and BayesCPi) for the specified traits.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!