A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fucosyl monosialoganglioside: Quantitative analysis of specific potential biomarkers of lung cancer in biological matrices using immunocapture extraction/tandem mass spectrometry. | LitMetric

Rationale: Certain lung cancer patients express elevated Fucosyl Monosialoganglioside (Fuc-GM1) in circulation compared to control groups. Several sensitive methods involving characterization of Fuc-GM1 have been reported. However, a highly specific and sensitive method for quantifying multiple potential Fuc-GM1 biomarkers present in various biological matrices has not been reported to date.

Methods: Individual Fuc-GM1 analogs in a commercially obtained standard mixture were characterized using HPLC/UV/MS and high-resolution mass spectrometry (HRMS). Proprietary antibodies, mAb1 and mAb2, were used to selectively capture and pre-concentrate the soluble and drug-bound forms of Fuc-GM1 molecules present in human serum and whole blood, eliminating the background matrix components. Immunocapture extraction (ICE) followed by HPLC/MS/MS was used to quantify specific Fuc-GM1 analogs in biological matrices.

Results: The concentration of individual Fuc-GM1 analogs in the standard mixture was estimated to be 7-34%, using HPLC/UV/MS. Using the standard mixture spiked into the biological matrices (100 μL), the lower limit of quantification (LLOQ) of each analog was 0.2-0.4 ng/mL with a dynamic range of up to 200 ng/mL. The applicability of the ICE-HPLC/MS/MS method was demonstrated by detecting endogenous Fuc-GM1 analogs present in rat blood and in several lung cancer cell lines.

Conclusions: This highly specific and sensitive HPLC/MS/MS method for quantifying individual potential Fuc-GM1 biomarkers in serum and whole blood can play a critical role in patient stratification strategies and during drug treatment. This method can be employed for monitoring both free (soluble) form and antibody drug-bound Fuc-GM1.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.8194DOI Listing

Publication Analysis

Top Keywords

fuc-gm1 analogs
16
lung cancer
12
biological matrices
12
standard mixture
12
fuc-gm1
10
fucosyl monosialoganglioside
8
mass spectrometry
8
highly specific
8
specific sensitive
8
method quantifying
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!