Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Coarctation of the aorta (CoA) is still challenging to diagnose in neonates with patent ductus arteriosus (PDA). Speckle tracking echocardiography allows reliable analysis of myocardial deformation in newborns and seems to provide important insides into regional changes in patients with left ventricular (LV) outflow tract obstruction.
Aims: To assess the interest of LV global longitudinal strain (GLS) measurement for predicting CoA in neonates with PDA and prenatal suspicion.
Methods: Prospective single-center study. Twenty-two newborns with prenatal suspicion of CoA were included. All newborns were evaluated in the first 12 hours of life. To assess the feasibility and the reproducibility of GLS, 14 healthy full-term newborns with PDA (group 3) were screened. CoA was diagnosed when DA closed, according to usual echocardiographic criteria.
Results: Six neonates developed CoA after DA closure (group 1) whereas 16 did not (group 2). Mean gestational age and birth weight were not different between the groups. GLS measurements were possible in 100%. Intra- and inter-observer variability of strain measurements was acceptable. GLS values were significantly lower in neonates who developed CoA (P=0.015). To predict CoA, cut-off value of -17.42% gave the best compromise for sensitivity (83%) and specificity (72%). Aortic arch dimensions were modestly correlated with strain values. The presence of a bicuspid aortic valve was not associated with significant lower GLS values.
Conclusion: LV GLS analysis is a feasible and reproducible echocardiographic technique in newborns with PDA. Newborns who will develop CoA seem to have lower values of GLS than healthy neonates. Further studies are needed to confirm these preliminary results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acvd.2018.03.010 | DOI Listing |