A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multi-wavelength spectrophotometric determination of hydrogen peroxide in water with peroxidase-catalyzed oxidation of ABTS. | LitMetric

In this study, a new spectrophotometric method was proposed for the measurement of hydrogen peroxide (HO) in aqueous solutions. The method was based on the peroxidase (POD)-catalyzed reaction in which 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) (ABTS) was oxidized to form the stable green radical (ABTS). The generated ABTS could be determined spectrophotometrically. The absorbance of the generated ABTS at 415 nm, 650 nm, 732 nm and 820 nm were linear with HO concentrations in the range of 0-40 μM. The sensitivities of the proposed ABTS method for HO determination at 415 nm, 650 nm, 732 nm and 820 nm were 6.29 × 10 M cm, 2.00 × 10 M cm, 2.54 × 10 M cm and 1.89 × 10 M cm, respectively. The oxidation of ABTS to generate ABTS in POD-catalyzed HO system at pH 6.0 was so fast that the determination time of the ABTS method was as short as 0.5 min. The stoichiometry of the reaction of HO and ABTS in the presence of POD was calculated as nearly 1:2 (1:1.92). The residual absorbance of the generated ABTS was also found to be stable within 30 min in natural waters. Low HO concentration in rainwater could be both measured by the ABTS method and the DPD method with high accuracy, however, HO concentration in wastewater contained rhodamine B could only be accurately measured with the ABTS method at 732 nm. Moreover, waste solutions after HO analysis with the proposed ABTS method were non-hazardous towards E. coli.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2017.11.091DOI Listing

Publication Analysis

Top Keywords

abts method
20
abts
14
generated abts
12
hydrogen peroxide
8
oxidation abts
8
method
8
absorbance generated
8
415 nm 650 nm
8
650 nm 732 nm
8
732 nm 820 nm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!