Magnetic resonance-guided radiation therapy (MRgRT) offers advantages for image guidance for radiotherapy treatments as compared to conventional computed tomography (CT)-based modalities. The superior soft tissue contrast of magnetic resonance (MR) enables an improved visualization of the gross tumor and adjacent normal tissues in the treatment of abdominal and thoracic malignancies. Online adaptive capabilities, coupled with advanced motion management of real-time tracking of the tumor, directly allow for high-precision inter-/intrafraction localization. The primary aim of this case series is to describe MR-based interventions for localizing targets not well-visualized with conventional image-guided technologies. The abdominal and thoracic sites of the lung, kidney, liver, and gastric targets are described to illustrate the technological advancement of MR-guidance in radiotherapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5985918PMC
http://dx.doi.org/10.7759/cureus.2422DOI Listing

Publication Analysis

Top Keywords

abdominal thoracic
12
image guidance
8
magnetic resonance-guided
8
resonance-guided radiation
8
radiation therapy
8
thoracic malignancies
8
era image
4
guidance magnetic
4
therapy abdominal
4
malignancies magnetic
4

Similar Publications

Claudin 18.2-targeting antibody-drug conjugate CMG901 in patients with advanced gastric or gastro-oesophageal junction cancer (KYM901): a multicentre, open-label, single-arm, phase 1 trial.

Lancet Oncol

January 2025

Department of Medical Oncology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University, Research Unit of Precision Diagnosis and Treatment for Gastrointestinal Cancer, Chinese Academy of Medical Sciences, Guangzhou, China. Electronic address:

Background: CMG901 is a novel first-in-class antibody-drug conjugate with a humanised anticlaudin 18.2 antibody linked to microtubule-disrupting agent monomethyl auristatin E. We aimed to assess the antitumour activity and safety of CMG901 in patients with advanced gastric or gastro-oesophageal junction cancer and other solid tumours.

View Article and Find Full Text PDF

We report a 28-year-old G2P0 at 24 weeks 5 days who presented for evaluation secondary to suspected skeletal dysplasia in her fetus. Fetal ultrasound imaging demonstrated foreshortened long bones by 9-10 weeks, multiple bowing deformities and fractures, 11 foreshortened paired ribs with fractures, decreased skull mineralization, frontal bossing, enlarged cavum septum pellucidi, and severe fetal growth restriction (< 2%). Findings were concerning for life limiting condition with thoracic circumference < 2.

View Article and Find Full Text PDF

Introduction: Deep inspiration breath hold technique has shown promise in reducing cardiac toxicity and improving patient outcomes. However, there is a lack of consensus regarding the implementation of abdominal breath hold technique and its impact on cardiac dose. This systematic review and meta-analysis aim to provide insights into the comparative effectiveness of abdominal and thoracic breath hold in mitigating cardiac toxicity during radiation therapy for left-sided breast cancer.

View Article and Find Full Text PDF

Purpose Of Review: The purpose of this review is to provide the most recent update and summary on the consideration, benefits and application of regional anesthesia in the ICU setting, as it pertains to the management of perioperative pain.

Recent Findings: Regional anesthesia and analgesia have become ubiquitous in the perioperative setting, with numerous indications and benefits. As integral part of the multimodal analgesia approach, various regional blocks have been increasingly utilized in critically ill patients.

View Article and Find Full Text PDF

Background And Aims: An arterial aneurysm is characterized by a localized expansion of a blood vessel relative to its original dimensions. Specifically, an abdominal aortic aneurysm (AAA) is identified as an aortic diameter measuring at least one and a half times the standard diameter at the renal artery level, approximately equivalent to 2.0 cm.

View Article and Find Full Text PDF