Recent studies have shown potential for using polarisation sensitive optical coherence tomography (PS-OCT) to study cartilage morphology, and to be potentially used as an in vivo, non-invasive tool for detecting osteoarthritic changes. However, there has been relatively limited ability of this method to quantify the subtle changes that occur in the early stages of cartilage degeneration. An established mechanical indenting technique that has previously been used to examine the microstructural response of articular cartilage was employed to fix the bovine samples in an indented state. The samples were subject to creep loading with a constant compressive stress of 4.5 MPa and, when imaged using PS-OCT, enabled birefringent banding patterns to be observed. The magnitude of the birefringence was quantified using the birefringence coefficient (BRC) and statistical analysis revealed that PS-OCT is able to detect and quantify significant changes between healthy and early osteoarthritic cartilage (p < 0.001). This presents a novel utilization of PS-OCT for future development as an in vivo assessment tool.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5988768PMC
http://dx.doi.org/10.1038/s41598-018-25982-9DOI Listing

Publication Analysis

Top Keywords

optical coherence
8
coherence tomography
8
quantifying birefringence
4
birefringence bovine
4
bovine model
4
model early
4
early osteoarthritis
4
osteoarthritis polarisation-sensitive
4
polarisation-sensitive optical
4
tomography mechanical
4

Similar Publications

Comprehensive multimodal imaging is essential for the precise clinical diagnostics of neovascular age-related macular degeneration (nAMD). Noninvasive optical coherence tomography (OCT) is of prime importance regarding the baseline examination, follow-up and monitoring during treatment. The OCT imaging in nAMD eyes enables a high-resolution assessment of the retinal micromorphology, which can be considerably disturbed in different layers.

View Article and Find Full Text PDF

Optimal frequency bands for pupillography for maximal correlation with HRV.

Sci Rep

January 2025

Centre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.

Assessing cognitive load using pupillography frequency features presents a persistent challenge due to the lack of consensus on optimal frequency limits. This study aims to address this challenge by exploring pupillography frequency bands and seeking clarity in defining the most effective ranges for cognitive load assessment. From a controlled experiment involving 21 programmers performing software bug inspection, our study pinpoints the optimal low-frequency (0.

View Article and Find Full Text PDF

Background: Nineteen-year follow-up after initial examination on patients with Axenfeld-Rieger anomaly or syndrome (ARAS) and coexisting Fuchs' endothelial dystrophy (FED). All individuals had previously been tested positive for the PITX2 (g.20 913 G>T) mutation.

View Article and Find Full Text PDF

Narrow elliptical motion at the outer hair cell-Deiters' cell junction explains disparate features of uniaxial displacement measurements.

Hear Res

January 2025

Columbia University Irving Medical Center, Department of Otolaryngology, Head and Neck Surgery, 180 Fort Washington Ave, New York, 10032, NY, USA; Columbia University, Department of Biomedical Engineering, 1210 Amsterdam Ave, New York, 10027, NY, USA.

Sound-evoked displacement responses at the outer hair cell-Deiters' cell junction (OHC-DC) are of significant interest in cochlear mechanics, as OHCs are believed to be in part responsible for active tuning enhancement and amplification. Motion in the cochlea is three-dimensional, and the architecture of the organ of Corti complex (OCC) suggests the presence and mechanical importance of all three components of motion. Optical coherence tomography (OCT) displacement measurements of OHC-DC motion from different experimental preparations often show disparate results, potentially due to OCT measuring only the motion component along the beam axis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!