AI Article Synopsis

Article Abstract

Background: Self-expandable percutaneous pulmonary valve implantation (PPVI) for native right ventricular outflow tract lesions is still in the clinical trial phase. The aim of this study is to present the result of feasibility study of a novel self-expandable knitted nitinol wire stent mounted with a treated trileaflet α-Gal-free porcine pericardial valve for PPVI.

Methods And Results: A feasibility study using Pulsta valve (TaeWoong Medical Co, Gyeonggi-do, South Korea) was designed for patients with severe pulmonary regurgitation in the native right ventricular outflow tract, and 6-month follow-up outcomes were reviewed. Ten tetralogy of Fallot patients were enrolled. Before PPVI, severe pulmonary regurgitation (mean pulmonary regurgitation fraction, 45.5%±7.2%; range, 34.9%-56%) and enlarged right ventricular volume (mean indexed right ventricular end-diastolic volume, 176.7±14.3 mL/m; range, 158.9-205.9 mL/m) were present. The median age at PPVI was 21.7±6.5 years (range, 13-36 years). Five patients were successfully implanted with 28 mm and the other 5 with 26 mm valves loaded on the 18F delivery cable. No significant periprocedural complications were noted in any patient. At the 6-month follow-up, indexed right ventricular end-diastolic volume was dramatically decreased to 126.3±20.3 mL/m (range, 99-164.2 mL/m), and the mean value of peak instantaneous pressure gradient between the right ventricle and the pulmonary artery decreased from 6.8±3.5 mm Hg (range, 2-12 mm Hg) before PPVI to 5.7±6.7 mm Hg (range, 2-12 mm Hg) without significant pulmonary regurgitation. There was no adverse event associated with the valve.

Conclusions: A feasibility study of the Pulsta valve for native right ventricular outflow tract lesions was completed successfully with planned Pulsta valve implantation and demonstrated good short-term effectiveness without serious adverse events.

Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02555319.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.118.006494DOI Listing

Publication Analysis

Top Keywords

pulsta valve
16
native ventricular
16
ventricular outflow
16
outflow tract
16
pulmonary regurgitation
16
valve implantation
12
feasibility study
12
self-expandable percutaneous
8
percutaneous pulmonary
8
valve
8

Similar Publications

Objectives: To describe the workflow and value of three-dimensional rotational angiography (3DRA) in percutaneous pulmonary valve implantation (PPVI).

Background: 3DRA offers visualization of the entire topography in the chest and may enhance safety and reduce the risk for complications in PPVI through improved pre-procedural planning and per-procedural guidance.

Methods: All PPVI procedures with the use of 3DRA performed between August 2011 and December 2022 were reviewed.

View Article and Find Full Text PDF

Background: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies.

Methods: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers.

View Article and Find Full Text PDF
Article Synopsis
  • Percutaneous pulmonary valve implantation (PPVI) is a minimally invasive method for treating severe pulmonary regurgitation in patients who have had tetralogy of Fallot repair, with the success relying on accurate valve sizing and performance.
  • Custom-modified cardiovascular mock loops were utilized to test 3D-printed pulmonary artery models for five patients, assessing various valve sizes under different cardiac conditions to enhance PPVI planning.
  • The experiments revealed that certain valve sizes in the mock models demonstrated improved hemodynamic performance compared to those actually implanted in two of the patients.
View Article and Find Full Text PDF

Background: Self-expanding pulmonary valve grafts have been designed for percutaneous pulmonary valve implantation (PPVI) in patients with native repaired right ventricular (RV) outflow tracts (RVOTs). However, their efficacy, in terms of RV function and graft remodelling remain unclear.

Methods: Patients with native RVOTs who received Venus P-valve (N = 15) or Pulsta valve (N = 38) implants between 2017 and 2022 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!