Background: The present study assessed the inter- and intra-observer reliability of tibial and femoral rotation measures after total knee arthroplasty (TKA), and evaluated the correlation between these measurement techniques and their clinical relevance.

Methods: Femoral rotation and tibial rotation were determined on 42 2D CT-scans made three-months after TKA. Reliability of the radiological measurements (including Berger's method, the anatomical tibial axis and the tibial tuberosity trochlear-groove) was assessed with 15 randomly selected patients measured twice by three observers. Functional outcomes were scored one-year postoperatively with the KSS, VAS pain, VAS satisfaction, KOOS, and Kujala.

Results: The inter- and intra-observer reliability of the rotational measurements ranged from good to excellent (ICC 0.67-0.98). Tibial rotation measured with the Berger technique was most reliable (ICC inter = 0.91; ICC intra = 0.96). No strong correlations were found between the different rotational measures or the clinical outcomes and rotational outliers.

Conclusions: Tibial rotation is most reliable measured with the technique described by Berger. There were no strong correlations found between the different tibial rotation measures or between the clinical outcomes and the rotational outliers. Further research is needed to gain more insight into optimal positioning and measuring rotation in TKA for clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2018.05.006DOI Listing

Publication Analysis

Top Keywords

tibial rotation
20
measurement techniques
8
tibial
8
rotation
8
total knee
8
knee arthroplasty
8
inter- intra-observer
8
intra-observer reliability
8
femoral rotation
8
rotation measures
8

Similar Publications

Revision of anterior cruciate ligament reconstruction presents various challenges not encountered in the primary settings, including malpositioned tunnels, tunnel widening, and the lack of consensus on the ideal graft to be used. This Technical Note describes a one-stage anterior cruciate ligament reconstruction revision using a bone-patellar tendon-bone autograft combined with lateral extra-articular tenodesis. This technique represents the ideal approach to tackle complex revision cases primarily characterized by tibial and femoral tunnel osteolysis and rotational knee instability.

View Article and Find Full Text PDF

The surgical approach for patellar instability usually refers to reconstruction of the medial patellofemoral ligament associated with an osteotomy of the tibial tuberosity or a trochleoplasty when required. The medial patellotibial ligament and the medial patellomeniscal ligament are secondary stabilizers of the patella. Despite this, both the medial patellotibial and patellofemoral ligaments aid in patellar rotation and tilt when the knee is flexed beyond 45°.

View Article and Find Full Text PDF

Minimum twenty-year follow-up of fixed-vs mobile-bearing total knee arthroplasty: Double blinded randomized trial.

J Clin Orthop Trauma

January 2025

Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.

Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.

View Article and Find Full Text PDF

Purpose: Medial meniscus ramp lesions (MMRLs), lateral meniscus posterior root tears (LMPRTs), and anterolateral complex injuries (ALCIs) are major secondary stabiliser injuries associated with anterior cruciate ligament (ACL) injuries. This study aimed to investigate the effect of the number of secondary stabiliser injuries on knee instability in ACL injuries.

Methods: Patients who underwent primary ACL reconstruction between January 2017 and May 2023 were enroled in this study.

View Article and Find Full Text PDF

Meniscal forces and knee kinematics are affected by tibial slope modifying high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

January 2025

Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.

Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!