  • The study explores a method to correct for respiratory motion during CT perfusion imaging in advanced lung cancer, aiming to improve measurement reproducibility.
  • Twenty-one patients with non-small-cell lung cancer participated, where a novel motion correction technique was applied and analyzed for its effectiveness.
  • Results showed significant improvements in intra- and inter-observer reproducibility of tumor blood flow estimates after motion correction, indicating it enhances accuracy in assessing lung tumor biology and treatment response.

Article Abstract

Purpose: CT perfusion (CTP) imaging assessment of treatment response in advanced lung cancer can be compromised by respiratory motion. Our purpose was to determine whether an original motion correction method could improve the reproducibility of such measurements.

Materials And Methods: The institutional review board approved this prospective study. Twenty-one adult patients with non-resectable non-small-cell lung cancer provided written informed consent to undergo CTP imaging. A motion correction method that consisted of manually outlining the tumor margins and then applying a rigid manual landmark registration algorithm followed by the non-rigid diffeomorphic demons algorithm was applied. The non-motion-corrected and motion-corrected images were analyzed with dual blood supply perfusion analysis software. Two observers performed the analysis twice, and the intra- and inter-observer variability of each method was assessed with Bland-Altman statistics.

Results: The 95% limits of agreement of intra-observer reproducibility for observer 1 improved from -84.4%, 65.3% before motion correction to -33.8%, 30.3% after motion correction (r = 0.86 and 0.97, before and after motion correction, p < 0.0001 for both) and for observer 2 from -151%, 96% to -49 %, 36 % (r = 0.87 and 0.95, p < 0.0001 for both). The 95% limits of agreement of inter-observer reproducibility improved from -168%, 154% to -17%, 25%.

Conclusion: The use of a motion correction method significantly improves the reproducibility of CTP estimates of tumor blood flow in lung cancer.

Key Points: • Tumor blood flow estimates in advanced lung cancer show significant variability. • Motion correction improves the reproducibility of CT blood flow estimates in advanced lung cancer. • Reproducibility of blood flow measurements is critical to characterize lung tumor biology and the success of treatment in lung cancer.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-018-5492-1DOI Listing

Publication Analysis

Top Keywords

motion correction
32
lung cancer
24
blood flow
20
flow estimates
12
advanced lung
12
correction method
12
motion
9
lung
8
correction
8
ctp imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!