Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Improper infection prevention practice associated with ultrasound probe use has been linked to increased infection risk, outbreaks, and death. Although guidelines for reprocessing and use of probes exist, it is unclear how extensively these have been adopted in practice.
Methods: Infection preventionists from U.S. health care facilities were surveyed (N = 358). The anonymous survey had 31 multiple choice, sliding scale, and text response questions. The survey was developed and deployed and the data were stored in the REDCap system.
Results: A high degree of noncompliance with U.S. guidelines was identified. Surface probes used in invasive procedures were not high-level disinfected or sterilized 15% (intraoperative) to 78% (peripheral line placements) of the time. Of invasive procedures, 5%-47% did not use sterile gel (same procedures, respectively). Of the participants, 20% were aware of instances where an ultrasound probe was used but was not correctly reprocessed. Extensive breaches of infection control guidelines were reported. The rapid expansion in use of ultrasound has brought clinical benefit but may be exposing patients to preventable infection risk.
Conclusions: Infection preventionists are well placed to act as major drivers of change based on their expertise and experience in the management of infection risk across facilities and health systems. They, along with clinicians responsible for probe use and reprocessing, should review practices relating to ultrasound in their facilities. Where practice does not comply with guidelines, policy and training should be updated to ensure patient safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajic.2018.03.025 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!