A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A systematic comparison and evaluation of three different Swept-Source interferometers for eye lengths biometry. | LitMetric

This study reviews the development of Swept-Source interferometers and compares systematically three different Swept-Source interferometer designs for biometric measurements of the eye. Principles characteristics, conveniences and accessibilities of the three developed systems are presented. The main difference between the three Swept-Source systems is the method of tuning the wavelength at the broadband optical amplifier. The implementation of a "quasi-phase-continuous method" (QPC) for wavelength tuning led to longer measuring depth but was more time-consuming. The wavelength tuning using a rotating polygon mirror scanner was faster. The wavelength tuning via Fourier Domain Mode Locking (FDML), where the tuning frequency f of the filter must be matched to the inverse cavity roundtrip time τ, achieved the widest tuning range combined with a rather better resolution and signal to noise ratio (SNR). The swept sources were compared using a fiber-optic based Michelson interferometer setup. Measurements of a self-made human model eye demonstrate excellent capturing of the biometric data, with all interfaces of eye optical components and their contours being clearly detected.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.zemedi.2018.05.004DOI Listing

Publication Analysis

Top Keywords

three swept-source
12
wavelength tuning
12
swept-source interferometers
8
tuning
6
systematic comparison
4
comparison evaluation
4
three
4
evaluation three
4
swept-source
4
eye
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!