Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Given the increased interest in public hygiene due to outbreaks of food poisoning, increased emphasis has been placed on developing novel monitoring systems for point-of-care testing (POCT) to evaluate pathogens causing foodborne illnesses. Here, we demonstrate a pathogen evaluation system utilizing simple film-based microfluidics, featuring simultaneous gene amplification, solution mixing, and electrochemical detection. To minimize and integrate the various functionalities into a single chip, patterned polyimide and polyester films were mainly used on a polycarbonate housing chip, allowing simple fabrication and alignment, in contrast to conventional polymerase chain reaction, which requires a complex biosensing system at a bench-top scale. The individual integrated sensing chip could be manually fabricated in 10 min. Using the developed film-based integrated biosensing chip, the genes from the pathogens causing foodborne illnesses were simultaneously amplified based on multiple designed microfluidic chambers and Hoechst 33258, which intercalates into double-stranded DNA, to generate the electrochemical signal. The target pathogen gene was accurately analyzed by square wave voltammetry (SWV) within the 25 s, while the gel electrophoresis required about 30 min. Based on the developed integrated biosensing chip, the 1.0 × 10 and 1.0 × 10 colony-forming unit (CFU) of Staphylococcus aureus and Escherichia coli were sensitively detected with high reproducibility in the 25 s. On the basis of the significant features of the film-based molecular analysis platform, we expect that the developed sensor could be applied to the screening of various pathogens as a POCT device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2018.03.061 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!