In this paper, we report on the development of a monolithic active pixel sensor for X-ray imaging using 0.2 µm fully depleted silicon-on-insulator (SOI)-based technology to support next generation astronomical satellite missions. Detail regarding low-noise dual-gain SOI based pixels with a charge sensitive amplifier and pinned depleted diode sensor structure is presented. The proposed multi-well sensor structure underneath the fully-depleted SOI allows the design of a detector with low node capacitance and high charge collection efficiency. Configurations for achieving very high charge-to-voltage conversion gain of 52 µV/e and 187 µV/e are demonstrated. Furthermore, in-pixel dual gain selection is used for low-noise and wide dynamic range X-ray energy detection. A technique to improve the noise performance by removing correlated system noise leads to an improvement in the spectroscopic performance of the measured X-ray energy. Taken together, the implemented chip has low dark current (44.8 pA/cm² at -30 °C), improved noise performance (8.5 e rms for high gain and 11.7 e rms for low gain), and better energy resolution of 2.89% (171 eV FWHM) at 5.9 keV using Fe and 1.67% (234 eV FWHM) at 13.95 keV using Am.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6022047 | PMC |
http://dx.doi.org/10.3390/s18061789 | DOI Listing |
Eur J Trauma Emerg Surg
January 2025
Cerrahpasa Faculty of Medicine, Department of Orthopaedics and Traumatology, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Background: The standard approach for addressing intra-articular calcaneal fractures involves open reduction with plate and screw fixation, with ongoing discourse regarding the application of grafts to address bone gaps. The aim of this study is the temporal comparison of the radiological and functional outcomes in patients undergoing surgery for intra-articular calcaneal fractures, with a specific focus on the use of bone grafts.
Methods: Thirty patients, comprising 13 with iliac grafts and 17 without, were enrolled in the study.
Pediatr Radiol
January 2025
Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
Background: Radiographic skeletal survey plays an important role in the diagnosis of infant abuse. Some practitioners have expressed concerns about the radiation exposure from this examination.
Objective: To utilize state-of-the-art hybrid computational phantoms to more accurately estimate radiation doses of skeletal surveys performed for suspected infant abuse.
Oral Radiol
January 2025
Department of Oral and Maxillofacial Radiology, The Nippon Dental University School of Life Dentistry, Tokyo, Japan.
Objective: The objective of this study was to evaluate the effectiveness of oblique radiographic projection using the intraoral paralleling technique in detecting various peri-implant bone defects.
Methods: Artificial mandibular models with appropriate radiopacity were created. An alveolar bone model without bone defects and models with 12 types of peri-implant bone defects (buccal, circumferential, and mixed types with different widths and depths) were created.
Background: The aim of this study was to explore the clinical value of serum procalcitonin (PCT) and C-reactive protein (CRP) levels in evaluating complications after endoscopic retrograde cholangiopancreatography (ERCP) in patients with common bile duct (CBD) stones.
Methods: Patients who were diagnosed with CBD stones and underwent ERCP from December 2021 to December 2023 were selected as the study subjects. According to whether postoperative complications occurred, they were divided into complication group (n = 28) and non-complication group (n = 132).
Radiology
January 2025
From the Department of Radiology, Duke University Hospital, 2301 Erwin Rd, Box 3808, Durham, NC 27701 (B.W.T., K.R.K., B.C.A., S.P.T., D.E.K., B.H., M.R.B., D.M., E.S., E.A.); Department of Biostatistics and Bioinformatics (N.F., S.M., A.E.) and Department of Medical Physics (W.P.S., E.S., E.A.), Duke University, Durham, NC.
Background Detection of hepatic metastases at CT is a daily task in radiology departments that influences medical and surgical treatment strategies for oncology patients. Purpose To compare simulated photon-counting CT (PCCT) with energy-integrating detector (EID) CT for the detection of small liver lesions. Materials and Methods In this reader study (July to December 2023), a virtual imaging framework was used with 50 anthropomorphic phantoms and 183 generated liver lesions (one to six lesions per phantom, 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!