A novel, single-phase, harmonic-driven, inertial piezoelectric linear motor using an automatic clamping mechanism was designed, fabricated, and tested to reduce the sliding friction and simplify the drive mechanism and power supply control of the inertial motor. A piezoelectric bimorph and a flexible hinge were connected in series to form the automatic clamping mechanism. The automatic clamping mechanism was used as the driving and clamping elements. A dynamic simulation by Simulink was performed to prove the feasibility of the motor. The finite element method software COMSOL was used to design the structure of the motor. An experimental setup was built to validate the working principle and evaluate the performance of the motor. The prototype motor outputted a no-load velocity of 3.178 mm/s at a voltage of 220 V and a maximum traction force of 4.25 N under a preload force of 8 N. The minimum resolution of 1.14 μm was achieved at a driving frequency of 74 Hz, a driving voltage of 50 V, and a preload force of 0 N.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5025732DOI Listing

Publication Analysis

Top Keywords

automatic clamping
16
clamping mechanism
16
inertial piezoelectric
8
piezoelectric linear
8
linear motor
8
preload force
8
motor
7
clamping
5
mechanism
5
motor driven
4

Similar Publications

Objective: The objective of this study was to improve long-term postoperative survival in a porcine cardiac valve surgery model by utilizing cardiopulmonary bypass (CPB) via left thoracotomy. The study aimed to share refined techniques and insights accumulated over years at a single-center animal clinical trial facility.

Method: A total of 196 Chinese Large White pigs weighing between 60 and 75 kg were used in the study.

View Article and Find Full Text PDF

Brain herniation can be a life-threatening condition, resulting in poor prognosis and higher fatality rates. We examined whether quantitative characteristics of sequential pupillary light reflex (PLR) could serve as biomarkers for identifying brain herniation in fatal acute stroke cases with anterior circulation involvement admitted to neurological intensive care unit (Neuro-ICU). Automatic pupillometer assessed PLR automatically every 4-6 hours, measuring eight specific features: NPi (Neurological pupil index) score, initial resting and constriction pupil size, constriction change, constriction velocity, constriction latency, and dilation velocity.

View Article and Find Full Text PDF

Inositol 1,4,5-Trisphosphate Receptor 1 Gain-of-Function Increases the Risk for Cardiac Arrhythmias in Mice and Humans.

Circulation

December 2024

Department of Physiology and Pharmacology, Libin Cardiovascular Institute, University of Calgary, Canada (B.S., M. Ni, Y.L., Z.S., H.W., H.-L.Z., J.W., D.B., S.C., W.G., J.Y., S.T., J.P.E., R.W., S.R.W.C.).

Article Synopsis
  • * Researchers identified 21 human ITPR1 GOF variants and created a mouse model with one of these variants (ITPR1-W1457G), which was found to be prone to stress-induced ventricular arrhythmias.
  • * Both mouse models and human data suggest that ITPR1 GOF variants increase Ca handling abnormalities and arrhythmia risk, with 7 rare ITPR1 variants in a human database showing similar GOF behavior linked to cardiac
View Article and Find Full Text PDF
Article Synopsis
  • A robotic probe manipulator for echocardiography aims to lessen the physical strain on cardiac radiologists while safely performing procedures, particularly for patients in the prone position.
  • Key design features include a combination of delta 3D printing technology and a soft end-effector, allowing the robot to operate without clamping issues while still reaching necessary cardiac windows.
  • Although expert doctors could achieve clinically acceptable ultrasound images using the robotic system, the scanning process took longer compared to manual methods, and image quality scores were lower for medical students using the robot.
View Article and Find Full Text PDF

PupilMetrics: a support system for preprocessing of pupillometric data and extraction of outcome measures.

Sci Rep

November 2024

Retinal Disorder Research Group, Department of Ophthalmology, University of Lausanne, Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, 15 av. de France, 1004, Lausanne, VD, Switzerland.

Article Synopsis
  • The pupil light reflex (PLR) is primarily controlled by a quick neural pathway that causes rapid pupillary constriction in response to light, but changes in pupil size from non-light stimuli or during darkness are slower and require careful analysis.
  • A new software tool called PupilMetrics was developed to automate the analysis of pupillometric data, effectively removing common artifacts and providing accurate measurements of pupil responses.
  • Testing with 29 participants showed that PupilMetrics significantly reduced analysis time from 30 hours to under 1 hour while maintaining high accuracy, making it a valuable resource for standardizing pupillometry in clinical and research settings.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!