A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Distance and speed of walking in individuals with trans-femoral amputation fitted with a distal weight-bearing implant. | LitMetric

Introduction: Preservation of femoral condyles in patients with knee disarticulation amputation (KDA) facilitates distal support inside the socket, compared to trans-femoral amputation (TFA), and allows the direct transfer of weight-bearing loads toward residual limbs.

Hypothesis: The hypothesis was that the gait distance and speed of TFA patients after a surgical femoral implant that allowed the distal support of the residuum would improve.

Material And Methods: Twenty-three TFA patients received a titanium implant that allowed the distal weight bearing of the residuum inside the socket. The post-intervention follow-up period lasted 14 months. Gait distance and speed were assessed with the 2-minute walk test (2MWT).

Results: The amputation etiology was trauma in 11 patients (48%), peripheral vascular disease in nine (39%) and oncologic disease in three (13%). The mean 2MWT distance was 103.6±34.7m prior to femoral implant and 128±38.9m at 14 months, which implies an improvement of 24% (p<0.001). The mean gait speed was 0.86±0.29m/s prior to femoral implant and 1.06±0.32m/s at 14 months (p<0.001).

Discussion: After implant placement, distance covered increased by 24%. This value is higher than those described by other groups, such as Rau (12.6%) and Darter (19.2%), who assessed improvement in distance covered with the 2MWT in a younger population and after completing different physiotherapy programs. Our results showed improved distance walked and gait speed as well as in the physical functioning score in TFA patients 14 months after receiving a femoral implant that permitted distal residuum loading.

Type Of Study: An experimental prospective study.

Level Of Proof: III, case-control study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2018.04.011DOI Listing

Publication Analysis

Top Keywords

distance speed
12
trans-femoral amputation
8
distal support
8
inside socket
8
gait distance
8
tfa patients
8
femoral implant
8
implant allowed
8
allowed distal
8
distance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!