Ultrasound-driven 4D MRI.

Phys Med Biol

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland. Center for Medical Image Analysis & Navigation, University of Basel, Allschwil, Switzerland.

Published: July 2018

We present an ultrasound-driven 4D magnetic resonance imaging (US-4DMRI) method for respiratory motion imaging in the thorax and abdomen. The proposed US-4DMRI comes along with a high temporal resolution, and allows for organ motion imaging beyond a single respiratory cycle. With the availability of the US surrogate both inside and outside the MR bore, 4D MR images can be reconstructed for 4D treatment planning and online respiratory motion prediction during radiotherapy. US-4DMRI relies on simultaneously acquired 2D liver US images and abdominal 2D MR multi-slice scans under free respiration. MR volumes are retrospectively composed by grouping the MR slices corresponding to the most similar US images. We present two different US similarity metrics: an intensity-based approach, and a similarity measure relying on predefined fiducials which are being tracked over time. The proposed method is demonstrated on MR liver scans of eight volunteers acquired over a duration of 5.5 min each at a temporal resolution of 2.6 Hz with synchronous US imaging at 14 Hz-17 Hz. Visual inspection of the reconstructed MR volumes revealed satisfactory results in terms of continuity in organ boundaries and blood vessels. In quantitative leave-one-out experiments, both US similarity metrics reach the performance level of state-of-the-art navigator-based approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aaca1dDOI Listing

Publication Analysis

Top Keywords

respiratory motion
8
motion imaging
8
temporal resolution
8
similarity metrics
8
ultrasound-driven mri
4
mri ultrasound-driven
4
ultrasound-driven magnetic
4
magnetic resonance
4
imaging
4
resonance imaging
4

Similar Publications

Chest imaging in children presents unique challenges due to varying requirements across age groups. For chest radiographs, achieving optimal images often involves careful positioning and immobilisation techniques. Antero-posterior projections are easier to obtain in younger children, while lateral decubitus radiographs are sometimes used when expiratory images are difficult to obtain and for free air exclusion.

View Article and Find Full Text PDF

Challenges in Rehabilitation of a Tetanus Patient With Severe Complications.

Cureus

December 2024

Department of Rehabilitation Medicine, School of Medicine, Showa University, Tokyo, JPN.

Tetanus is a rare but life-threatening neurological disorder caused by neurotoxins produced by . Although mortality rates have significantly decreased with modern intensive care, severe cases remain challenging due to prolonged Intensive Care Unit (ICU) stays, complications, and rehabilitation barriers. We report the case of an 81-year-old male with a history of hypertension and femoral neck fracture who developed severe tetanus following a contaminated forehead laceration.

View Article and Find Full Text PDF

WildPose: A long-range 3D wildlife motion capture system.

J Exp Biol

January 2025

African Robotics Unit, University of Cape Town, Cape Town, 7700, Western Cape, South Africa.

Understanding and monitoring wildlife behavior is crucial in ecology and biomechanics, yet challenging due to the limitations of current methods. To address this issue, we introduce WildPose, a novel long-range motion capture system specifically tailored for free-ranging wildlife observation. This system combines an electronically controllable zoom-lens camera with a LiDAR to capture both 2D videos and 3D point cloud data, thereby allowing researchers to observe high-fidelity animal morphometrics, behavior and interactions in a completely remote manner.

View Article and Find Full Text PDF

Background: Management of respiratory motion during radiation therapy is essential for accurate dose delivery and minimizing the risk to organs. In diagnostic imaging, respiratory monitoring is required for confirmation of breath-hold and four-dimensional computed tomography (CT) reconstruction. Although respiratory monitoring systems are widely used in radiation therapy, they are not often used for diagnostic imaging, where they could improve image quality.

View Article and Find Full Text PDF

Fenestrated/branched endovascular aortic repair emerges as the primary therapeutic modality for intricate aortic pathologies encompassing the paravisceral and thoracoabdominal segments, where bridging stent grafts (BSGs) play a vital role in linking the primary aortic endograft with target vessels. Bridging stent grafts can be categorized mainly into self-expanding stent grafts (SESGs) and balloon-expandable stent grafts (BESGs). Physiological factors significantly influence post-complex endovascular aortic repair BSG behaviour, impacting clinical outcomes of SESGs and BESGs in different but overlapping ways.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!