Goal: To evaluate the analytical parameters of a lateral flow (LF) pepsin immunoassay (Peptest) and assess its suitability in the diagnostics of gastroesophageal reflux disease (GERD).

Background: Peptest is a noninvasive assay to analyze pepsin in saliva, intended for use in GERD diagnostics. Although commercialized, fundamental studies on its performance are missing. The assay therefore requires basic analytical parameter evaluation to assess its suitability in clinical practice.

Study: Assay reaction's time dependence, reader device repeatability, and individual LF devices and longitudinal pepsin concentration reproducibility in individual subjects was evaluated. Salivary pepsin was analyzed in 32 GERD patients with extraesophageal reflux symptoms and 13 healthy individuals.

Results: The assay's signal increase is not completed at the recommend readout time and continues to increase for another 25 minutes. The relative standard deviation of measurement was good when using the same LF device, ranging from 2.3% to 12.9%, but the reproducibility of 10 different individual LF devices was poor. The random error when analyzing the same saliva sample on 10 LF devices was as high as 36 ng/mL and this value is thus suggested as the positivity cut-off. Pepsin concentration in individual subjects during a 10-day period varied significantly. The sensitivity of the Peptest was 36.8% in the group with acid reflux and 23.1% in the group with weakly acid reflux. The specificity was 61.5%.

Conclusions: The Peptest assay's sensitivity and specificity is low, the results are highly variable and it should not be used as a near-patient diagnostic method in primary care.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MCG.0000000000001066DOI Listing

Publication Analysis

Top Keywords

analytical parameters
8
gastroesophageal reflux
8
reflux disease
8
assess suitability
8
individual devices
8
pepsin concentration
8
reproducibility individual
8
individual subjects
8
acid reflux
8
peptest
5

Similar Publications

: A common problem in pediatric orthopedics is leg length discrepancy (LLD). In adulthood, this may result in overload and degenerative changes in the lumbar spine, hip, and knee joints of the longer limb, and the fixed equinus position of the foot of the shorter limb. Surgical treatment using temporary epiphysiodesis with eight-plate implants is a minimally invasive, safe, and patient-tolerated procedure in LLD.

View Article and Find Full Text PDF

In this paper, we demonstrate that torsional surface elastic waves can propagate along the curved surface of a metamaterial elastic rod (cylinder) embedded in a conventional elastic medium. The crucial parameter of the metamaterial rod is its elastic compliance s44(1)ω, which varies as a function of frequency ω analogously to the dielectric function εω in Drude's model of metals. As a consequence, the elastic compliance s44(1)ω can take negative values s44(1)ω<0 as a function of frequency ω.

View Article and Find Full Text PDF

Tribomechanical Properties of Glazes for Ceramic Tiles: A Novel Protocol for Their Characterization.

Materials (Basel)

December 2024

Department of Civil, Chemical, Environmental and Materials Engineering (DICAM), University of Bologna, Via Terracini 28, 40131 Bologna, Italy.

The aim of the work is to design and validate a characterization protocol for glazes used in the ceramic tile industry to lead manufacturers and researchers towards the formulation of glazes with enhanced wear resistance properties. The focus of the protocol is addressed to determine surface parameters that strongly depend on glaze formulation and firing temperature. This protocol includes analytical (e.

View Article and Find Full Text PDF

The surface roughness of hole machining greatly influences the mechanical properties of parts, such as early fatigue failure and corrosion resistance. The boring and trepanning association (BTA) deep hole drilling with axial vibration assistance is a compound machining process of the tool cutting and the guide block extrusion. At the same time, the surface of the hole wall is also ironed by the axial large amplitude and low-frequency vibration of the guide block.

View Article and Find Full Text PDF

This study introduces a novel analytical framework for investigating the vibration characteristics of functionally graded carbon nanotube-reinforced composite (FG-CNTRC) elliptical cylindrical shells under arbitrary boundary conditions. Unlike previous studies that focused on simplified geometries or specific boundary conditions, this work combines the least-squares weighted residual method (LSWRM) with an adapted variational principle, addressing high-order vibration errors and ensuring continuity across structural segments. The material properties are modeled using an extended rule of mixtures, capturing the effects of carbon nanotube volume fractions and distribution types on structural dynamics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!