Background: Early detection and tracking of breast cancer treatment-related lymphedema have been helped by quantitative assessment methods and parameters, including bioelectrical impedance spectroscopy and tissue dielectric constant (TDC). Such measurements are evaluated with respect to interarm differences or ratios that (when exceeding specified thresholds) are suggestive of lymphedema. Specific threshold ratios depend on the assessment method and have been reported for arms. However, there is far less information available on thresholds to assess lymphedema that manifests in at-risk hands and essentially nothing known about TDC ratios in healthy hands. Such information is essential to establish reference values from which lymphedema threshold TDC values may be estimated. The specific aim of this research was to determine such interhand TDC ratios applicable to both young and mature women.

Methods And Results: A total of 70 women (35 under 30 years of age, YOUNG, and 35 over 50 years of age, MATURE) participated after signing an approved institutional review board informed consent. TDC values of the hand dorsum web were measured bilaterally in triplicate with participants in a supine resting position. Results showed MATURE TDC values to be about 15% less than YOUNG (p < 0.01) on dominant and nondominant hands, but no statistical difference in dominant/nondominant interarm ratios (1.026 ± 0.100).

Conclusions: Based on this data set's overall mean and two standard deviation value, an age-independent interhand TDC threshold ratio of 1.23 emerges as potentially useful for lymphedema detection. This is a good initial start threshold that is usable in future clinical and research assessments.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lrb.2017.0065DOI Listing

Publication Analysis

Top Keywords

tdc values
12
reference values
8
tissue dielectric
8
dielectric constant
8
tdc ratios
8
years age
8
tdc
6
lymphedema
5
ratios
5
values assessing
4

Similar Publications

Cephalometric analysis is the primary diagnosis method in orthodontics. In our previous study, the algorithm was developed to estimate cephalometric landmarks from lateral facial photographs of patients with normal occlusion. This study evaluates the estimation accuracy by the algorithm trained on a dataset of 2320 patients with added malocclusion patients and the analysis values.

View Article and Find Full Text PDF

Purpose: To complement the current research on altered white matter integrity in children with non-lesional temporal lobe epilepsy (NL-TLE), especially the correlation between diffusion metrics and clinical characteristics, so as to provide imaging evidence for clinical practice.

Methods: Children with temporal lobe epilepsy and no lesions on magnetic resonance imaging (MRI) were retrospectively collected from 2016.01.

View Article and Find Full Text PDF

Assessing Tissue Dielectric Constant Values in Tumor Bearing and Healthy Breasts.

Lymphat Res Biol

December 2024

Gentle Touch Breast Diagnostics, Coral Springs, Florida, USA.

This study aimed to investigate, characterize, and provide quantitative reference data on tissue dielectric constant (TDC) values of female breasts when measurements were made to 5 mm depths and determine the utility of these measurements to differentiate between benign and malignant breast tumors. Breast TDC was measured bilaterally in 82 women just prior to an ultrasound-guided diagnostic biopsy of one tumor in one breast. TDC was measured in triplicate over the tumor and the contralateral healthy breast.

View Article and Find Full Text PDF

Health Economic Evaluation of Antimicrobial Stewardship, Procalcitonin Testing, and Rapid Blood Culture Identification in Sepsis Care: A 90-Day Model-Based, Cost-Utility Analysis.

Pharmacoecon Open

January 2025

Department of Critical Care Medicine, Faculty of Medicine and Dentistry, University of Alberta and Alberta Health Services, 2-124 Clinical Sciences Building, 8440 112 Street NW, Edmonton, Alberta, T6G 2B7, Canada.

Objective: We evaluated the cost-effectiveness of a bundled intervention including an antimicrobial stewardship program (ASP), procalcitonin (PCT) testing, and rapid blood culture identification (BCID), compared with pre-implementation standard care in critically ill adult patients with sepsis.

Methods: We conducted a decision tree model-based cost-effectiveness analysis alongside a previously published pre- and post-implementation quality improvement study. We adopted a public Canadian healthcare payer's perspective.

View Article and Find Full Text PDF

Skin tissue dielectric constant: Time of day and skin depth dependence.

Clin Physiol Funct Imaging

January 2025

Department of Medical Education, Dr. Kiran C. Patel College of Allopathic Medicine, Nova Southeastern University, Fort Lauderdale, Florida, USA.

Background: Skin water measurements are used to investigate skin physiology, clinically study dermatological issues, and for conditions like diabetes, oedema, and lymphedema with measurements done at various times of day (TOD). One method used is skin's tissue dielectric constant (TDC), often clinically measured to a single depth of 2.5 mm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!