A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is Regular Knee Radiograph Reliable Enough to Assess the Knee Prosthesis Position? | LitMetric

Is Regular Knee Radiograph Reliable Enough to Assess the Knee Prosthesis Position?

J Arthroplasty

Department of Orthopaedics, Chulabhorn International College of Medicine, Thammasat University, Pathum Thani, Thailand.

Published: September 2018

Background: Proper knee alignment and prosthesis position may theoretically provide better surgical results and increase longevity of total knee arthroplasty. The 3-feet standing long radiograph (LR) is the gold standard for assessment of these parameters. However, the conventional standing regular knee radiograph (RR) is still being used because of convenience and lower cost. We conducted a study to investigate the accuracy of RR compared to LR in assessing the coronal plane prosthesis position.

Methods: We conducted a retrospective cross-sectional study in 100 knee radiographs in 88 patients with knee prostheses. The picture archiving and communications system was used to produce digitized radiographs and perform the angle measurements. LR images were cropped to the same size as the RRs to eradicate rotation error. The femoral component angle (FCA), tibial component angle (TCA), and tibiofemoral angle (TFA) were measured and analyzed by Student t-test. Pearson's correlation coefficient was used to assess interobserver and intraobserver reliability.

Results: The RR measurements resulted in a mean increment of 1.3° (95% confidence interval [CI], 0.9°-1.6°; P < .001) for FCA and 1.4° (95% CI, 1.0°-1.9°; P < .001) for TFA compared to LR. The TCAs were similar between 2 techniques (0.2° mean difference; 95% CI, 0°-0.4°; P = .11). RR provided very strong intraobserver reproducibility but only strong interobserver reliability for FCA and TCA while LR provided very strong correlation for all angles.

Conclusion: RR overestimation of FCA and TFAs in a valgus alignment was minimal, suggesting RR could be an acceptable alternative to LR.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2018.05.014DOI Listing

Publication Analysis

Top Keywords

regular knee
8
knee radiograph
8
component angle
8
provided strong
8
knee
6
radiograph reliable
4
reliable assess
4
assess knee
4
knee prosthesis
4
prosthesis position?
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!