Using an orbit shield during volume perfusion CT: is it useful protection or an obstacle?

Clin Radiol

University Institute of Diagnostic and Interventional Neuroradiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Published: September 2018

Aim: To evaluate the image quality and artefacts resulting from in-plane orbit shielding during computed tomography (CT) perfusion and to assess the possibility of artefact reduction using the iterative metal artefact reduction (iMAR) algorithm.

Materials And Methods: Twenty-eight perfusion CT examinations obtained from 20 patients using orbit shields were included in this study. Source images and perfusion maps were analysed retrospectively to detect the type and extent of artefacts. Original images were compared with images processed using the iMAR algorithm. The extent of artefacts was categorised into three groups: orbital/frontal, middle fossa, and posterior fossa. Types of artefacts in source images were categorised as noise, streak, beam hardening, or a combination of those, and types of artefacts in perfusion maps were categorised as: noise, image distortion, areas with missing colour codes, or incorrect colour-coding.

Results: All source images evaluated showed artefacts related to orbit shielding and 85.7% reached the posterior fossa. In 92.8% of scans, perfusion maps showed artefacts, mostly as incorrect colour codes. Of the perfusion maps with artefacts, 92.3% reached the posterior fossa. After application of the iMAR algorithm, an increase in the extent of artefacts was observed in 93% of perfusion maps, and no improvement of image quality was noted.

Conclusion: Orbit shields cause significant artefacts if used for in-plane shielding during whole-brain CT perfusion, and render areas at the level of the shield undiagnosable. Usage of an orbit shield during whole-brain CT perfusion is not recommended, so alternative methods for reducing the radiation dose are advisable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2018.05.003DOI Listing

Publication Analysis

Top Keywords

perfusion maps
20
source images
12
extent artefacts
12
posterior fossa
12
perfusion
10
artefacts
10
orbit shield
8
image quality
8
artefacts in-plane
8
orbit shielding
8

Similar Publications

On the Effect of the Patient Table on Attenuation in Myocardial Perfusion Imaging SPECT.

EJNMMI Phys

January 2025

Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital (Ruhr University Bochum), Medical Faculty OWL (Bielefeld University), Bad Oeynhausen, Germany.

Background: The topic of the effect of the patient table on attenuation in myocardial perfusion imaging (MPI) SPECT is gaining new relevance due to deep learning methods. Existing studies on this effect are old, rare and only consider phantom measurements, not patient studies. This study investigates the effect of the patient table on attenuation based on the difference between reconstructions of phantom scans and polar maps of patient studies.

View Article and Find Full Text PDF

Sensitivity of Functional Arterial Spin Labelling in Detecting Cerebral Blood Flow Changes.

Br J Hosp Med (Lond)

December 2024

Department of Neurology, Wuhan Brain Hospital, General Hospital of Yangtze River Shipping, Wuhan, Hubei, China.

Arterial spin labelling (ASL) is a non-invasive magnetic resonance imaging (MRI) method. ASL techniques can quantitatively measure cerebral perfusion by fitting a kinetic model to the difference between labelled images (tag images) and ones which are acquired without labelling (control images). ASL functional MRI (fMRI) provides quantitative perfusion maps by using arterial water as an endogenous tracer instead of depending on vascular blood oxygenation level.

View Article and Find Full Text PDF

A deep learning approach versus expert clinician panel in the classification of posterior circulation infarction.

Neuroimage Clin

January 2025

Department of Neurology and Neurophysiology, Liverpool Hospital, Sydney, NSW, Australia; South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia; Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.

Background: Posterior circulation infarction (POCI) is common. Imaging techniques such as non-contrast-CT (NCCT) and diffusion-weighted-magnetic-resonance-imaging commonly fail to detect hyperacute POCI. Studies suggest expert inspection of Computed Tomography Perfusion (CTP) improves diagnosis of POCI.

View Article and Find Full Text PDF

To validate the clinical feasibility of deep learning-driven magnetic resonance angiography (DL-driven MRA) collateral map in acute ischemic stroke. We employed a 3D multitask regression and ordinal regression deep neural network, called as 3D-MROD-Net, to generate DL-driven MRA collateral maps. Two raters graded the collateral perfusion scores of both conventional and DL-driven MRA collateral maps and measured the grading time.

View Article and Find Full Text PDF

Background And Purpose: Prolonged venous transit (PVT), derived from computed tomography perfusion (CTP) time-to-maximum (T) maps, reflects compromised venous outflow (VO) in acute ischemic stroke due to large vessel occlusion (AIS-LVO). Poor VO is associated with worse clinical outcomes, but pre-treatment markers predictive of PVT are not well described.

Methods: We conducted a retrospective analysis of 189 patients with anterior circulation AIS-LVO who underwent baseline CT evaluation, including non-contrast CT, CT angiography, and CTP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!