Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The performance of pressurized metered dose inhalers (MDIs) is affected by formulation and device variables that impact delivered dose, aerodynamic particle size distribution, and consequently lung deposition and therapeutic effect. Specific formulation variables of relevance to two commercially available products-Proventil® HFA [albuterol sulfate (AS) suspension] and Qvar® [beclomethasone dipropionate (BDP) solution]-were evaluated to determine their influence on key performance attributes measured experimentally with in vitro cascade impaction studies. These commercial MDIs, utilized as model systems, provided mid-points for a design of experiments (DoE) plan to manufacture multiple suspension and solution MDI formulations. The experimental results were utilized as input variables in a computational dosimetry model to predict the effects of MDI formulation variables on lung deposition. For the BDP solution DoE MDIs, increased concentrations of surfactant oleic acid (0-2% w/w) increased lung deposition from 24 to 46%, whereas changes in concentration of the cosolvent ethanol (7-9% w/w) had no effect on lung deposition. For the AS suspension DoE MDIs, changes in oleic acid concentration (0.005-0.25% w/w) did not have significant effects on lung deposition, whereas lung deposition decreased from 48 to 26% as ethanol concentration increased from 2 to 20% w/w, and changes in micronized drug volumetric median particle size distribution (X, 1.4-2.5 μm) increased deposition in the tracheobronchial airways from 5 to 11%. A direct correlation was observed between fine particle fraction and predicted lung deposition. These results demonstrate the value of using dosimetry models to further explore relationships between performance variables and lung deposition.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1208/s12249-018-1071-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!