Aim: To define variables for the evaluation of keratoconus progression and to determine cut-off values.

Methods: In this retrospective cohort study (2010-2016), 265 eyes of 165 patients diagnosed with keratoconus underwent two Scheimpflug measurements (Pentacam) that took place 1 year apart ±3 months. Variables used for keratoconus detection were evaluated for progression and a correlation analysis was performed. By logistic regression analysis, a keratoconus progression index (KPI) was defined. Receiver-operating characteristic curve (ROC) analysis was performed and Youden Index calculated to determine cut-off values.

Results: Variables used for keratoconus detection showed a weak correlation with each other (eg, correlation r=0.245 between RPImin and Kmax, p<0.001). Therefore, we used parameters that took several variables into consideration (eg, D-index, index of surface variance, index for height asymmetry, KPI). KPI was defined by logistic regression and consisted of a Pachymin coefficient of -0.78 (p=0.001), a maximum elevation of back surface coefficient of 0.27 and coefficient of corneal curvature at the zone 3 mm away from the thinnest point on the posterior corneal surface of -12.44 (both p<0.001). The two variables with the highest Youden Index in the ROC analysis were D-index and KPI: D-index had a cut-off of 0.4175 (70.6% sensitivity) and Youden Index of 0.606. Cut-off for KPI was -0.78196 (84.7% sensitivity) and a Youden Index of 0.747; both 90% specificity.

Conclusions: Keratoconus progression should be defined by evaluating parameters that consider several corneal changes; we suggest D-index and KPI to detect progression.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2017-311651DOI Listing

Publication Analysis

Top Keywords

keratoconus progression
12
evaluation keratoconus
8
determine cut-off
8
variables keratoconus
8
keratoconus detection
8
analysis performed
8
keratoconus
5
progression
4
progression aim
4
aim define
4

Similar Publications

This systematic review evaluates the long-term effectiveness of scleral lenses in improving visual outcomes, patient satisfaction, and safety in patients with keratoconus. A systematic search of six databases (PubMed, Embase, Web of Science, Scopus, Cochrane Library, and MEDLINE) was performed following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The inclusion criteria included studies with more than or equal to three months of follow-up, included a minimum of 20 keratoconus patients, published after year 2020 and outcomes reporting visual acuity, comfort or quality of life.

View Article and Find Full Text PDF

Purpose: To investigate the effectiveness and safety of accelerated epithelium-on crosslinking to stabilize tomographically suspicious fellow eyes of young patients with unilateral clinically evident keratoconus (KC) compared with observation alone.

Methods: This retrospective observational study included 43 fellow eyes of 43 young patients with unilateral clinically evident KC who completed a 24-month follow-up. Twenty-four eyes underwent accelerated epithelium-on crosslinking [epi-on corneal crosslinking (CXL) group] and 19 eyes were observed (observation group).

View Article and Find Full Text PDF

Advances in Corneal Diagnostics Using Machine Learning.

Bioengineering (Basel)

November 2024

Department of Electrical & Electronic Engineering, College of Engineering, Universiti Tenaga Nasional, Kajang 43000, Malaysia.

This paper provides comprehensive insights into the cornea and its diseases, with a particular focus on keratoconus. This paper explores the cornea's function in maintaining ocular health, detailing its anatomy, pathological conditions, and the latest developments in diagnostic techniques. Keratoconus is discussed extensively, covering its subtypes, etiology, clinical manifestations, and the application of the Q-value for quantification.

View Article and Find Full Text PDF

Keratoconus is a burden to health systems and patients worldwide. Corneal collagen crosslinking (CXL) treatment has been shown abroad to be cost-effective for treating progressive keratoconus. However, no cost-effectiveness studies have been performed in Brazil.

View Article and Find Full Text PDF

Keratoconus is a multifaceted corneal ectatic disorder characterized by a range of genetic and environmental risk factors. While genetic predisposition significantly influences global disease prevalence rates as well as severity and progression rates, emerging evidence highlights the critical interplay between environmental factors and genetic susceptibility. This article provides a comprehensive overview of environmental risk factors implicated in the onset and progression of keratoconus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!