Purpose: The aim was to investigate the variation of the arterial input function (AIF) within and between various DCE MRI sequences.

Material And Methods: A dynamic flow-phantom and steady signal reference were scanned on a 3T MRI using fast low angle shot (FLASH) 2d, FLASH3d (parallel imaging factor (P) = P0, P2, P4), volumetric interpolated breath-hold examination (VIBE) (P = P0, P3, P2 × 2, P2 × 3, P3 × 2), golden-angle radial sparse parallel imaging (GRASP), and time-resolved imaging with stochastic trajectories (TWIST). Signal over time curves were normalized and quantitatively analyzed by full width half maximum (FWHM) measurements to assess variation within and between sequences.

Results: The coefficient of variation (CV) for the steady signal reference ranged from 0.07-0.8%. The non-accelerated gradient echo FLASH2d, FLASH3d, and VIBE sequences showed low within sequence variation with 2.1%, 1.0%, and 1.6%. The maximum FWHM CV was 3.2% for parallel imaging acceleration (VIBE P2 × 3), 2.7% for GRASP and 9.1% for TWIST. The FWHM CV between sequences ranged from 8.5-14.4% for most non-accelerated/accelerated gradient echo sequences except 6.2% for FLASH3d P0 and 0.3% for FLASH3d P2; GRASP FWHM CV was 9.9% versus 28% for TWIST.

Conclusion: MRI acceleration techniques vary in reproducibility and quantification of the AIF. Incomplete coverage of the k-space with TWIST as a representative of view-sharing techniques showed the highest variation within sequences and might be less suited for reproducible quantification of the AIF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2018.04.022DOI Listing

Publication Analysis

Top Keywords

parallel imaging
12
acceleration techniques
8
arterial input
8
input function
8
steady signal
8
signal reference
8
maximum fwhm
8
gradient echo
8
quantification aif
8
sequences
5

Similar Publications

Addressing the issue of excessive manual intervention in discharging fermented grains from underground tanks in traditional brewing technology, this paper proposes an intelligent grains-out strategy based on a multi-degree-of-freedom hybrid robot. The robot's structure and control system are introduced, along with analyses of kinematics solutions for its parallel components and end-effector speeds. According to its structural characteristics and working conditions, a visual-perception-based motion control method of discharging fermented grains is determined.

View Article and Find Full Text PDF

Cascaded Feature Fusion Grasping Network for Real-Time Robotic Systems.

Sensors (Basel)

December 2024

College of Engineering, Huaqiao University, Quanzhou 362021, China.

Grasping objects of irregular shapes and various sizes remains a key challenge in the field of robotic grasping. This paper proposes a novel RGB-D data-based grasping pose prediction network, termed Cascaded Feature Fusion Grasping Network (CFFGN), designed for high-efficiency, lightweight, and rapid grasping pose estimation. The network employs innovative structural designs, including depth-wise separable convolutions to reduce parameters and enhance computational efficiency; convolutional block attention modules to augment the model's ability to focus on key features; multi-scale dilated convolution to expand the receptive field and capture multi-scale information; and bidirectional feature pyramid modules to achieve effective fusion and information flow of features at different levels.

View Article and Find Full Text PDF

The adaptation of 3D printing techniques within the construction industry has opened new possibilities for designing and constructing cementitious materials efficiently and flexibly. The layered nature of extrusion-based concrete printing introduces challenges, such as interlayer weaknesses, that compromise structural integrity and mechanical performance. This experimental study investigates the influence of interlayer orientation and the presence of cold joints (CJ) on mechanical properties, such as stiffness and strength.

View Article and Find Full Text PDF

How to Implement Clinical 7T MRI-Practical Considerations and Experience with Ultra-High-Field MRI.

Bioengineering (Basel)

December 2024

Department of Radiology, Mayo Clinic Arizona, 5711 E Mayo Blvd, Phoenix, AZ 85054, USA.

The implementation of clinical 7T MRI presents both opportunities and challenges for advanced medical imaging. This tutorial provides practical considerations and experiences with 7T MRI in clinical settings. We first explore the history and evolution of MRI technology, highlighting the benefits of increased signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and susceptibility at 7T.

View Article and Find Full Text PDF

DeSPPNet: A Multiscale Deep Learning Model for Cardiac Segmentation.

Diagnostics (Basel)

December 2024

Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.

Background: Cardiac magnetic resonance imaging (MRI) plays a crucial role in monitoring disease progression and evaluating the effectiveness of treatment interventions. Cardiac MRI allows medical practitioners to assess cardiac function accurately by providing comprehensive and quantitative information about the structure and function, hence making it an indispensable tool for monitoring the disease and treatment response. Deep learning-based segmentation enables the precise delineation of cardiac structures including the myocardium, right ventricle, and left ventricle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!