MR in microscopy can non-invasively image the morphology of living tissue, which is of particular interest in studying the mammalian brain. Many studies use live animals for basic research on brain functions, disease pathogenesis, and drug development. However, in vitro systems are on the rise, due to advantages such as the absence of a blood-brain barrier, predictable pharmacokinetics, and reduced ethical restrictions. Hence, they present an inexpensive and adequate technique to answer scientific questions and to perform drug screenings. Some publications report the use of acute brain slices for MR microscopy studies, but these only permit single measurements over several hours. Repetitive MR measurements in longitudinal studies demand an MR-compatible setup which allows cultivation for several days or weeks, and hence properly functioning in vitro systems. Organotypic hippocampal slice cultures (OHSC) are a well-established and robust in vitro system which still exhibits most histological hallmarks of the hippocampal network in vivo. An MR compatible incubation platform is introduced in which OHSC are cultivated according to the interface method following Stoppini et al. In this cultivation method a tissue slice is placed onto a membrane with nutrition medium underneath and a gas atmosphere above, where the air-tissue interface perpendicular to the B field induces strong artefacts. We introduce a handling protocol that suppresses these artefacts and increases signal quality significantly to acquire high resolution images of tissue slices. An additional challenge is the lack of available of MR microscopy equipment suitable for small animal scanners. A Lenz lens with an attached capacitor can dramatically increase the SNR in these cases, and wirelessly bring the detection system in close proximity to the sample without compromising the OHSC system through the introduction of wired detectors. The resultant signal gain is demonstrated by imaging a PFA-fixed brain slice with a 72 mm diameter volume coil without a Lenz lens, and with a broadband and a self-resonant Lenz lens. In our setting, the self-resonant Lenz lens increases the SNR 10-fold over using the volume coil only.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mri.2018.05.010 | DOI Listing |
Phys Med Biol
December 2024
Department of Chemistry, Lakehead University, Thunder Bay, ON P7B5E1, Canada.
The need for increased sensitivity in magnetic resonance imaging (MRI) is crucial for its advancement as an imaging modality. The development of passive Lenz Resonators (LRs) for effective RF magnetic field (B) focusing will improve MRI sensitivity via local amplification of MRI signal, thereby leading to more efficient diagnosis and patient treatment.While there are methods for amplifying the signal from specific nuclei in MRI, such as hyperpolarization, a general solution will be more advantageous and would work in combination with these preexisting methods.
View Article and Find Full Text PDFCont Lens Anterior Eye
August 2024
College of Health & Life Sciences, Aston University, Birmingham, United Kingdom. Electronic address:
Cataract surgery including intraocular lens (IOL) insertion, has been refined extensively since the first such procedure by Sir Harold Ridley in 1949. The intentional creation of monovision with IOLs using monofocal IOL designs has been reported since 1984. The first reported implantation of multifocal IOLs was published in 1987.
View Article and Find Full Text PDFClin Ophthalmol
May 2024
University of California, San Francisco, Department of Ophthalmology, San Francisco, CA, USA.
Purpose: To compare the outcomes of the Tecnis Eyhance ICB00 IOL, designed to enhance intermediate vision, to a conventional Tecnis Monofocal ZCB00 IOL.
Methods: This retrospective analysis compared two cohorts of patients undergoing lens replacement surgery with bilateral implantation of the Tecnis ICB00 or the Tecnis ZCB00 IOL (383 patients in each group). Monocular and binocular uncorrected distance (UDVA), intermediate (UIVA; 66cm), and near (UNVA; 40cm) visual acuities, refractive predictability, and patient-reported outcomes were compared.
Cont Lens Anterior Eye
August 2024
Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom.
Presbyopia is often the first sign of ageing experienced by humans. Standardising terminology and adopting it across the BCLA CLEAR Presbyopia reports, improves consistency in the communication of the evidence-based understanding of this universal physiological process. Presbyopia can be functionally and psychologically debilitating, especially for those with poor access to eyecare.
View Article and Find Full Text PDFOphthalmol Ther
April 2024
Glaukos Corporation, One Glaukos Way, Aliso Viejo, CA, 92656, USA.
Introduction: This prospective, multicenter, randomized, double-masked pivotal phase 3 trial evaluated the efficacy and safety of the travoprost intracameral SE-implant (slow-eluting implant, the intended commercial product) and FE-implant (fast-eluting implant, included primarily for masking purposes) compared to twice-daily (BID) timolol ophthalmic solution, 0.5% in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT).
Methods: The trial enrolled adult patients with OAG or OHT with an unmedicated mean diurnal intraocular pressure (IOP) of ≥ 21 and unmedicated IOP ≤ 36 mmHg at each diurnal timepoint (8 A.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!