Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: CD157/Bst1 glycoprotein is expressed in >85% of malignant pleural mesotheliomas and is a marker of enhanced tumor aggressiveness.
Results: , mesothelial cells (malignant and non-malignant) released CD157 in soluble form or as an exosomal protein. , sCD157 is released and can be measured in pleural effusions by ELISA. Significantly higher levels of effusion sCD157 were detected in patients with malignant pleural mesothelioma than in patients with non-mesothelioma tumors or with non-malignant conditions. In our patient cohort, the area under the receiver-operating characteristic curve for sCD157 that discriminated malignant pleural mesothelioma from all other causes of pleural effusion was 0.685, cut-off (determined by the Youden Index) = 23.66 ng/ml (62.3% sensitivity; 73.93% specificity). Using a cut-off that yielded 95.58% specificity, measurement of sCD157 in cytology-negative effusions increased sensitivity of malignant pleural mesothelioma diagnosis from 34.42% to 49.18%.
Conclusions: Evaluation of soluble CD157 in pleural effusions provides a diagnostic aid in malignant mesothelioma.
Methods: Soluble CD157 (sCD157) was detected biochemically in culture supernatants of malignant and non-malignant mesothelial cells, and in pleural effusions from various pathological conditions. An ELISA system was established to measure the concentration of sCD157 in fluids, and extended to analyze sCD157 in pleural effusions from a cohort of 295 patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978265 | PMC |
http://dx.doi.org/10.18632/oncotarget.25237 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!