Urine dipstick results may vary between operators/methods. The magnitude of variation across the veterinary field is currently unknown. The aim of this study was to compare the precision of urine dipstick results between standard direct visual and automated reading methods when performed by several operators. Urine samples were pooled and divided into three aliquots: one plain, one with glucose and one with serum. Final year students, veterinary surgeons and veterinary nurses, blinded to each sample, were then asked to perform dipstick analysis with direct visualisation and an automated analyser, and their technique was observed. A subsequent session was undertaken with samples which had pH titrated to achieve an acidic, neutral or alkaline value. Sixty-four veterinary students, 20 veterinary surgeons and seven veterinary nurses performed the first (n=61) or second (n=30) part of the study. Precision was greater using the automated reader. The most common observed technique errors were: lack of sample mixing, for both visual and automated methods, and not timing readings as per manufacturer instructions when performing visual analysis. This study suggests that in an environment with multiple operators, as is the case in veterinary teaching or large private hospitals, automated urine dipstick reading improves precision of results.

Download full-text PDF

Source
http://dx.doi.org/10.1136/vr.104841DOI Listing

Publication Analysis

Top Keywords

urine dipstick
16
visual automated
12
automated methods
8
students veterinary
8
veterinary surgeons
8
surgeons veterinary
8
veterinary nurses
8
veterinary
7
automated
6
urine
5

Similar Publications

Background: Urinary tract infections are prone to overdiagnosis, and reflex urine culture protocols offer a valuable opportunity for diagnostic stewardship in this arena. However, there is no recommended standard testing approach. Cancer patients are often excluded from reflex urine culture protocols, especially if severely immunosuppressed or neutropenic.

View Article and Find Full Text PDF

Background: Urinalysis is a commonly performed test for the diagnosis and prognosis of kidney disease in hospitalized patients. It involves examining the chemical composition of the urine and microscopy to examine the cells and casts. In clinical settings, urinalysis is frequently delayed by several hours after sample collection and held at room temperature.

View Article and Find Full Text PDF

Home Urine Dipstick Screening for Bladder and Kidney Cancer in High-Risk Populations in England: A Microsimulation Study of Long-Term Impact and Cost-Effectiveness.

Pharmacoeconomics

January 2025

Sheffield Centre for Health and Related Research (SCHARR), School of Medicine and Population Health, The University of Sheffield, Regent Court, 30 Regent Street, Sheffield, UK.

Background: Testing high-risk populations for non-visible haematuria may enable earlier detection of bladder cancer, potentially decreasing mortality. This research aimed to assess the cost-effectiveness of urine dipstick screening for bladder cancer in high-risk populations in England.

Methods:  A microsimulation model developed in R software was calibrated to national incidence data by age, sex and stage, and validated against mortality data.

View Article and Find Full Text PDF

Objectives: Urinalysis is widely used and is also frequently requested in emergency situations for screening hypovolemia, urinary tract infections, diabetes, ketoacidosis and hematuria. Our aim was to evaluate the impact of reporting urinary sediment in emergency department specimens with the Sysmex UN system.

Methods: We evaluated urinalyses requested by the emergency department over a three-month period and examined red blood cell count interference, compared leukocyte esterase dipsticks to cytofluorimetric leukocyte count and nitrites to cytofluorimetric bacterial count.

View Article and Find Full Text PDF

Methods for Diagnosing Proteinuria: When to Use Which Test, and Why.

Am J Kidney Dis

December 2024

Medical Outpatient Department, University Hospital Basel, University Basel, Switzerland. Electronic address:

Proteinuria plays a central role in the diagnosis of kidney disease and has a high prognostic value. The test methods used differ considerably regarding impact on test accuracy, sensitivity, and specificity. Therefore, knowledge of the methodology is crucial for the interpretation of the results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!