A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mixed Model Analysis of Between-Subject Variability in Overnight Corneal Swelling and Deswelling With Silicone Hydrogel Lenses. | LitMetric

Purpose: To model between subject variability of corneal swelling (CS) and deswelling after overnight wear of silicone hydrogel (SiHy) contact lenses.

Methods: A total of 29 neophyte subjects wore 12 SiHy lenses with central transmissibility range of 31 to 211 Dk/t units on separate nights, in random order, and on one eye only. The contralateral eye served as the control. Central corneal thickness was measured using digital optical pachymetry before lens insertion, immediately after lens removal on waking, then 20, 40 minutes, 1, 2, and 3 hours later. Mixed modelling was conducted for simultaneous analysis of group and between-subject effects of CS and deswelling.

Results: The best model for overnight CS versus Dk/t was linear with a random intercept showing constant between-subject differences in CS for different Dk/t values. The best fit for corneal deswelling versus time was a curvilinear random intercept and random slope model. About 90% of the total between-subject deswelling variance in either lens or control eyes was due to the intercept variability with much less (∼10%) being due to the variability of the individual deswelling rate (slope). Subject age, sex, and ametropia were not predictors of individual corneal swelling in the swelling versus Dk/t analysis. Age, however, was a significant (inverse) predictor of the rate of corneal deswelling, only in lens-wearing eyes.

Conclusions: A large proportion of variability in corneal swelling is because of subject-specific differences in corneal response to hypoxia. This shows that "low swellers" and "high swellers" actually do exist.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.17-23352DOI Listing

Publication Analysis

Top Keywords

corneal swelling
16
corneal
8
swelling deswelling
8
silicone hydrogel
8
variability corneal
8
versus dk/t
8
random intercept
8
corneal deswelling
8
deswelling
6
variability
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!