A protocol that combines gas chromatography and a high-sensitivity micro Clark-type electrode is described to quantify hydrogen production across gas and solution phases for systems operating at very low currents such as dye-sensitized H-evolving photocathodes. Data indicate that a significant fraction of H remains in aqueous solution even after several hours of experiments. Using this protocol, re-evaluation of a dye-sensitized H-evolving photocathode based on a dye-catalyst dyad showed a reproducible 66% increase of the faradaic efficiency compared with previously reported headspace GC measurements [Kaeffer et al., J. Am. Chem. Soc., 2016, 138, 12308-12311]. This dyad was based on an organic push-pull dye where donor and acceptor are separated by one thiophene group. Insertion of a second thiophene group between the donor and acceptor led to a more efficient system with 30% improved faradaic efficiency for H evolution.