Purpose: The purpose of this study was to determine the relationship between HbA1c values and retinal sensitivity at central 10° using the MP-1 microperimeter.
Methods: A prospective study was carried out on 32 healthy subjects (control group) and 60 diabetic patients. The diabetic patients were divided into 2 groups. Group 1 comprised of 30 patients without diabetic retinopathy (DR) and group 2 had 30 patients with mild non-proliferative DR. A full-threshold microperimetry of the central 10° of retina (the macula) was performed on all subjects, utilizing 32 points with the MP-1. The relationship between light sensitivity and HbA1c value was calculated using linear regression analysis.
Results: Total mean sensitivity at 10° for group 1 without DR, group 2 with mild NPDR and control group were 18.67±0.83, 17.98±1.42 and 19.45±0.34 (dB), respectively. There was a significant difference in total mean retinal sensitivity at 10° between the 3 groups (F(2,89)=18.14, p=0.001). A simple linear regression was calculated to predict HbA1c based on retinal sensitivity. A significant regression equation was found (F(1,90)=107.61, p=0.0001, with an R of 0.545). The linear regression analysis revealed that there was a 0.64dB decline in mean retinal sensitivity within the central 10° diameter with an increase of 1mmHg of HbA1c.
Conclusion: Retinal sensitivity at the central 10° of the macula is affected by changes in HbA1c values.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6612021 | PMC |
http://dx.doi.org/10.1016/j.optom.2018.03.007 | DOI Listing |
Photodiagnosis Photodyn Ther
December 2024
Department of Ophthalmology, Tianjin Medical University General Hospital, Tianjin, China, Ministry of Education International Joint Laboratory of Ocular Diseases, Tianjin, China, Tianjin Key Laboratory of Ocular Trauma, Tianjin, China, Tianjin Institute of Eye Health and Eye Diseases, Tianjin, China, China-UK "Belt and Road" Ophthalmology. Electronic address:
Background: This study investigated the association between photoreceptor structural restoration and visual function outcomes in patients undergoing surgery for closed macular holes (MHs). Using adaptive optics scanning laser ophthalmoscopy (AOSLO) and microperimetry, we aimed to provide a more detailed understanding of photoreceptor recovery and visual improvement in closed MHs.
Methods: We conducted a retrospective observational study of 31 eyes of 28 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling to treat idiopathic MHs.
Acta Ophthalmol
December 2024
Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.
Purpose: The relationship between retinal morphology, as assessed by optical coherence tomography (OCT), and retinal function in microperimetry (MP) has not been well studied, despite its increasing importance as an essential functional endpoint for clinical trials and emerging therapies in retinal diseases. Normative databases of healthy ageing eyes are largely missing from literature.
Methods: Healthy subjects above 50 years were examined using two MP devices, MP-3 (NIDEK) and MAIA (iCare).
BMC Ophthalmol
December 2024
Vitreoretina Department National Eye Center Cicendo Eye Hospital, Bandung, Indonesia.
Purpose: To evaluate early response of retinal sensitivity (RS) and retinal morphology in diabetic macular edema (DME) patients after intravitreal anti-vascular endothelial growth factor (anti-VEGF) treatment.
Methods: Sixteen eyes of 12 DME patients were included in this study conducted prospectively. All eyes underwent functional and morphologic examination of the macular area using microperimetry and optical coherence tomography (OCT) before and after intravitreal anti-VEGF injection.
J Funct Biomater
December 2024
Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.
Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality.
View Article and Find Full Text PDFIndian J Ophthalmol
January 2025
Department of Retina and Vitreous, University of Pittsburgh School of Medicine, Medical Retina and Vitreoretinal Surgery, Pittsburg, PA, USA.
Purpose: To evaluate various supervised machine learning (ML) statistical models to predict anatomical outcomes after macular hole (MH) surgery using preoperative optical coherence tomography (OCT) features.
Methods: This retrospective study analyzed OCT data from idiopathic MH eyes at baseline and at 1-month post-surgery. The dataset was split 80:20 between training and testing.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!