Background: Point-of-care ultrasonography (POCUS) has recently become a useful tool that intensivists are incorporating into clinical practice. However, the incorporation of ultrasonography in critical care in developing countries is not straightforward.

Methods: Our objective was to investigate current practice and education regarding POCUS among Brazilian intensivists. A national survey was administered to Brazilian intensivists using an electronic questionnaire. Questions were selected by the Delphi method and assessed topics included organizational issues, POCUS technique and training patterns, machine availability, and main applications of POCUS in daily practice.

Results: Of 1533 intensivists who received the questionnaire, 322 responded from all of Brazil's regions. Two hundred and five (63.8%) reported having access to an ultrasound machine dedicated to the intensive care unit (ICU); however, this was more likely in university hospitals than in non-university hospitals (80.6 vs. 59.6%; risk ratio [RR] = 1.35 [1.16-1.58], p = 0.002). The main applications of POCUS were ultrasound-guided central vein catheterization (49.4%) and bedside echocardiographic assessment (33.9%). Two hundred and fifty-eight (80.0%) reported having at least one POCUS-trained intensivist in their staff (trained units). Trained units were more likely to perform routine ultrasound-guided jugular vein catheterization than non-trained units (38.6 vs. 16.4%; RR = 2.35 [1.31-4.23], p = 0.001). The proportion of POCUS-trained intensivists and availability of a dedicated ultrasound machine were both independently associated with performing ultrasound-guided jugular vein catheterization (RR = 1.91 [1.32-2.77], p = 0.001) and (RR = 2.20 [1.26-3.29], p = 0.005), respectively.

Conclusions: A significant proportion of Brazilian ICUs had at least one intensivist with POCUS capability in their staff. Although ultrasound-guided central vein catheterization constitutes the main application of POCUS, adherence to guideline recommendations is still suboptimal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5972134PMC
http://dx.doi.org/10.1186/s13613-018-0397-3DOI Listing

Publication Analysis

Top Keywords

vein catheterization
16
point-of-care ultrasonography
8
intensive care
8
national survey
8
brazilian intensivists
8
main applications
8
applications pocus
8
ultrasound machine
8
ultrasound-guided central
8
central vein
8

Similar Publications

The formula-based estimation of the right internal jugular venous (IJV) catheterization depth can be inaccurate when using ultrasound guidance. External landmark-based and radiological landmark-based methods have been proposed as alternatives to estimate the insertion depth. This study aimed to evaluate these methods using transesophageal echocardiography (TEE)-guided insertion depth as the reference.

View Article and Find Full Text PDF

Inferior vena cava (IVC) anomalies are rare congenital pathologies related to variations of agenesis, hypoplasia, or atresia, predisposing patients to thromboembolic events secondary to an alteration in venous drainage with resultant stasis. This is a case report of a 27-year-old male without significant medical history presenting for a fall after playing recreational basketball with associated pain and swelling in his left lower extremity. After his symptoms progressively worsened, he came to the emergency room for an evaluation where an ultrasound (US) of the extremity showed extensive deep vein thromboses (DVT).

View Article and Find Full Text PDF

Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.

Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.

View Article and Find Full Text PDF

Background: Craniotomy is highly susceptible to postoperative pneumonia, which significantly impacts the outcomes of patients undergoing such procedures. Our study aims to examine the risk factors associated with postoperative pneumonia and establish a predictive model with a nomogram to assess this risk.

Methods: We conducted a matched 1:1 case-control study involving 831 adult patients undergoing craniotomy at our hospital.

View Article and Find Full Text PDF

Background/objectives: This study identified early neonatal factors predicting pre-discharge mortality among extremely preterm infants (EPIs) or extremely low birth weight infants (ELBWIs) in China, where data are scarce.

Methods: We conducted a retrospective analysis of 211 (92 deaths) neonates born <28 weeks of gestation or with a birth weight <1000 g, admitted to University Affiliated Hospitals from 2013 to 2024 in Guangzhou, China. Data on 26 neonatal factors before the first 24 h of life and pre-discharge mortality were collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!