Progress in low dose health risk research: Novel effects and new concepts in low dose radiobiology.

Mutat Res Rev Mutat Res

Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), DRF, Fontenay-aux-Roses 18 route du Panorama, 92265, Fontenay-aux-Roses Cedex, France. Electronic address:

Published: November 2018

People are more often exposed to low as opposed to high doses of ionising radiation (IR). Knowledge on the health risks associated with exposures to ionising radiation above 100 mGy is quite well established, while lower dose risks are inferred from higher level exposure information (ICRP). The health risk assessments are mainly based on epidemiological data derived from the atomic bombing of Hiroshima and Nagasaki, medical exposure studies and follow-up studies after nuclear accidents. For the estimation of long-term stochastic radiation health effects (such as cancer) and radiation protection purposes, a linear non-threshold (LNT) model is applied. However, the general validity of the LNT hypothesis for extrapolations from effects of high to low doses (<100 mGy) and low dose-rates (<6 mGy/h) has been questioned as epidemiological studies are statistically limited at low doses and unable to evaluate low dose and low dose-rate health risks (UNSCEAR). Thus, uncertainties on health risks need to be clarified with the help of mechanistic studies. The European Network of Excellence DoReMi (2010-2016) was designed to address some of the existing uncertainties and to identify research lines that are likely to be most informative for low dose risk assessment. The present review reports the results obtained from studies addressing the induction of cancer and non-cancer effects by low dose IR as well as on individual radiation sensitivity. It is shown that low dose and low dose-rate effects are the result of complex network responses including genetic, epigenetic, metabolic and immunological regulation. Evidence is provided for the existence of nonlinear biological responses in the low and medium dose range as well as effects other than the classical DNA damage. Such effects may have a bearing on the quantitative and qualitative judgements on health effects induced by low dose radiations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mrrev.2018.04.001DOI Listing

Publication Analysis

Top Keywords

low dose
8
health risk
8
ionising radiation
8
progress low
4
health
4
dose health
4
risk novel
4
novel effects
4
effects concepts
4
concepts low
4

Similar Publications

Assessment of Emphysema on X-ray Equivalent Dose Photon-Counting Detector CT: Evaluation of Visual Scoring and Automated Quantification Algorithms.

Invest Radiol

October 2024

From the Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore, Rome, Italy (A.R.L.).

Objectives: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.

Methods: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read.

View Article and Find Full Text PDF

Nowadays, direct oral anticoagulants (DOACs) represent the gold standard for venous thromboembolism (VTE) treatment and VTE secondary prophylaxis; nevertheless, the percentage of elderly patients in major trials and literature data about DOACs usage for VTE secondary prophylaxis in the elderly are scant. Our retrospective study tried to evaluate low-dose DOACs efficacy and safety for elderly VTE secondary prophylaxis in a real-life setting. A cohort of 73 patients (≥ 75 years) considered at high risk of VTE recurrence was treated with apixaban 2.

View Article and Find Full Text PDF

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia.

PLoS One

December 2024

Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.

Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.

View Article and Find Full Text PDF

Food allergies are a global health problem that continues to grow annually, with a prevalence of more than 10%. Shrimp allergy is the most common and life-threatening allergy. There is no cure for food allergies, but shrimp allergen extract (SAE) offers promise as a treatment through allergen-specific immunotherapy (AIT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?