Purpose: To evaluate the long-term effectiveness of 6.6 mm long flapless-placed single implants loaded immediately or early loaded at 6 weeks.
Materials And Methods: Thirty patients each received two single Nanotite External Hex Biomet 3i implants, which were then randomly allocated to be either immediately or early loaded, according to a split-mouth design. Implants had to be inserted with a torque superior to 40 Ncm. Provisional crowns were put in slight occlusal contact and replaced by definitive crowns 3 months after loading. Patients were followed for 9 years after loading. Outcome measures were implant failures, biological and biomechanical complications, peri-implant marginal bone level changes and patient preference.
Results: A total of 29 implants were immediately loaded, while 31 were early loaded. Nine years after loading, three patients dropped out. One implant failed in each group within 2 months after loading. One patient asked for the immediately loaded crown to be remade for aesthetic reasons and then again to have both metal-ceramic crowns replaced by full ceramic crowns. Another patient had his immediately loaded crown remade after repeated debonding. Six patients from each group experienced complications, the difference being not statistically significant (difference of proportions = 0.00; 95% CI -0.20 to 0.20, P = 1.000). Peri-implant bone loss was 0.60 mm for patients with immediately loaded implants and 0.46 mm for early loaded ones, which was not significantly different (mean difference = 0.14 mm, 95% CI -0.13 to 0.41, P = 0.283). All but one patient had no preference for either procedure after 9 years.
Conclusions: Flapless-placed 6.6 mm long single implants can be immediately loaded and remain successful up to 9 years after loading. Conflict-of-interest statement:
Download full-text PDF |
Source |
---|
J Prosthodont
January 2025
Department of Community Medicine and Health Care, University of Connecticut Health Center, Farmington, Connecticut, USA.
Purpose: The primary objective of this retrospective study was to evaluate the survival outcomes of immediately loaded acrylic resin complete arch fixed implant-supported prosthesis (CAFIP) fabricated from the denture conversion protocol. The secondary objective was to evaluate the early implant survival outcomes associated with these prostheses.
Material And Methods: A retrospective chart review was conducted to study the clinical outcomes data of immediately loaded conversion prostheses and immediately loaded implants.
Nurs Rep
January 2025
Decker College of Nursing and Health Sciences, Binghamton University, Binghamton, NY 13902, USA.
: Decreased well-being may be a precursor to mental health challenges. Mental health visits for 5-11-year-old children increased by 24% from 2019 to 2020. COVID-19 led to record high levels of anxiety and depression in young children.
View Article and Find Full Text PDFJ Funct Biomater
January 2025
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-372 Wrocław, Poland.
This study focuses on the development and evaluation of the OrthoNail hybrid intramedullary implant for lower limb lengthening in patients requiring significant skeletal reconstruction. The implant addresses the challenges in load-bearing during rehabilitation, providing a robust solution that is capable of supporting physiological loads. Mechanical tests, including axial compression, tension, torsion, and 3,4-point bending, determined the implant's load capacity and fatigue resistance, while finite element analysis assessed stress distributions in bone tissue and around screw holes during single-leg stance, with boundary conditions derived from Orthoload database data.
View Article and Find Full Text PDFHeliyon
January 2025
School of Human Movement and Nutrition Science, The University of Queensland, Brisbane, Australia.
The human ankle joint complex, consisting of calcaneus, talus, and tibia, is often simplified as a single functional ankle joint, neglecting the motion of the talus. Understanding the individual contributions of the talus and calcaneus is crucial for comprehending ankle joint complex function in healthy populations, and alterations in function that may exist in clinical conditions. To achieve accurate bone kinematics, high-resolution biplanar videoradiography was used with participants engaged in walking and running (n = 9) and hopping (n = 9) with no overlap in participants.
View Article and Find Full Text PDFMater Today Bio
February 2025
Kunming Institute of Zoology, Chinese Academy of Sciences, PR China.
The early treatment of Osteonecrosis of Femoral Head (ONFH) remains a clinical challenge. Conventional Bone Marrow Mesenchymal Stem Cell (BMSC) injection methods often result in unsatisfactory outcomes due to mechanical cell damage, low cell survival and retention rates, inadequate cell matrix accumulation, and poor intercellular interaction. In this study, we employed a novel cell carrier material termed "3D Microscaffold" to deliver BMSCs, addressing these issues and enhancing the therapeutic effects of cell therapy for ONFH.