A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mandibular Flexure and Peri-Implant Bone Stress Distribution on an Implant-Supported Fixed Full-Arch Mandibular Prosthesis: 3D Finite Element Analysis. | LitMetric

Purpose: The purpose of this study was to evaluate and compare the effect of three mandibular full-arch superstructures on the peri-implant bone stress distribution during mandibular flexure caused by mid-opening (27 mm) and protrusion mandibular movements.

Materials And Methods: Three-dimensional finite element models were created simulating six osseointegrated implants in the jawbone. One model simulated a 1-piece framework and the other simulated 2-piece and 3-piece frameworks. Muscle forces with definite direction and magnitude were exerted over areas of attachment to simulate multiple force vectors of masticatory muscles during mandibular protrusion and opening.

Results: During the movement of 27.5 mm jaw opening, the 1-piece and 3-piece superstructures showed the lowest values of bone stress around the mesial implants, gradually increasing towards the distal position. During the protrusion movement, bone stress increased compared to opening for any implant situation and for a divided or undivided framework. The 3-piece framework showed the highest values of peri-implant bone stress, regardless of the implant situation.

Conclusions: The undivided framework provides the best biomechanical environment during mandibular protrusion and opening. Protrusion movement increases the peri-implant bone stress. The most mesial implants have the lowest biomechanical risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5899843PMC
http://dx.doi.org/10.1155/2018/8241313DOI Listing

Publication Analysis

Top Keywords

bone stress
24
peri-implant bone
16
mandibular flexure
8
stress distribution
8
finite element
8
mandibular protrusion
8
stress mesial
8
mesial implants
8
protrusion movement
8
undivided framework
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!