Purpose: Using a cadaveric model simulating clinical situations experienced during open reduction and internal fixation of proximal phalangeal fractures, the aim of this study was to evaluate the relationship between level of training and the rates of short, long, and ideal screw length selection based on depth gauge use without fluoroscopy assistance.
Methods: A dorsal approach to the proximal phalanx was performed on the index, middle, and ring fingers of 4 cadaveric specimens, and 3 drill holes were placed in each phalanx. Volunteers at different levels of training then measured the drill holes with a depth gauge and selected appropriate screw sizes. The rates of short, long, and ideal screw selection were compared between groups based on level of training. Ideal screws were defined as a screw that reached the volar cortex but did not protrude more than 1 mm beyond it.
Results: Eighteen participants including 3 hand fellowship-trained attending physicians participated for a total of 648 selected screws. The overall rate of ideal screw selection was lower than expected at 49.2%. There was not a statistically significant relationship between rate of ideal screw selection and higher levels of training. Attending surgeons were less likely to place short screws and screws protruding 2 mm or more beyond the volar cortex CONCLUSIONS: Overall, the rate of ideal screw selection was lower than expected. The most experienced surgeons were less likely to place short and excessively long screws.
Clinical Relevance: Based on the low rate of ideal screws, the authors recommend against overreliance on depth gauging alone when placing screws during surgery. The low-rate ideal screw length selection highlights the potential for future research and development of more accurate technologies to be used in screw selection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhsa.2018.04.011 | DOI Listing |
BMC Oral Health
December 2024
Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand.
Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.
Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.
Cureus
November 2024
CISNE Spine Academy, Star Medica Hospital, Autonomous University of Chihuahua, Chihuahua, MEX.
Study Design: This is a cross-sectional survey.
Objectives: This study aimed to evaluate the availability and knowledge of navigation technologies for educational purposes and patient management in spine surgeons in Latin America.
Methods: A cross-sectional study was conducted among Latin American Spine Association members using a comprehensive 16-question survey to evaluate their knowledge and practices regarding navigation in spinal surgery.
Patient Saf Surg
December 2024
Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich, 8091, Switzerland.
Background: Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years.
View Article and Find Full Text PDFJ Neurosurg Spine
December 2024
1Department of Orthopaedic Surgery, The Och Spine Hospital/Columbia University Irving Medical Center, New York, New York.
Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.
Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.
J Child Orthop
December 2024
Department of Orthopaedics, Children's Hospital Boston, Boston, MA, USA.
Purpose: The purpose of this study is to develop an evidence-based algorithm for the management of symptomatic bipartite patella in the pediatric and adolescent population based on a systemic review of the published literature.
Methods: A systematic review of the literature was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines on PubMed and Embase, selecting for studies discussing the management of symptomatic bipartite patella.
Results: Five studies met criteria, involving 315 knees (314 patients, average age 15.