A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Possibility of chest wall dose reduction using volumetric-modulated arc therapy (VMAT) in radiation-induced rib fracture cases: comparison with stereotactic body radiation therapy (SBRT). | LitMetric

The present study compares dosimetric parameters between volumetric-modulated arc therapy (VMAT) and 3D conformal radiation therapy (3D-CRT) in lung tumors adjacent to the chest wall treated with stereotactic body radiation therapy (SBRT). The study focused on the radiation dose to the chest wall of 16 patients who had developed radiation-induced rib fractures (RIRF) after SBRT using 3D-CRT. The targets in all patients were partially overlapping with the fractured ribs, and the median overlapping rib-PTV distance was 0.4 cm. Stereotactic body radiation therapy was re-planned for all patients. The prescribed dose was 48 Gy in four fractions to cover at least 95% of the planning target volume (PTV). Evaluated dosimetric factors included D98% and the conformation number (CN) of the PTV, the D2cm3, V40 and V30 of the fractured ribs, the V30 of the chest wall, and the Dmean, V20 and V5 of the lung. A comparison of 3D-CRT with the VMAT plan for PTV revealed that CN was significantly improved in the VMAT plan, whereas D98% did not significantly differ between the two plans. Regarding organs at risk (OARs), the D2cm3, V40 and V30 of fractured ribs, the V30 of the chest wall, and the Dmean, V20 and V5 of the lung, were significantly decreased in the VMAT plan. We concluded that the dose to OARs such as ribs and chest wall could be reduced with improved target conformity using VMAT instead of 3D-CRT for SBRT to treat peripheral lung tumors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5967448PMC
http://dx.doi.org/10.1093/jrr/rry012DOI Listing

Publication Analysis

Top Keywords

chest wall
24
radiation therapy
16
stereotactic body
12
body radiation
12
fractured ribs
12
vmat plan
12
volumetric-modulated arc
8
arc therapy
8
therapy vmat
8
radiation-induced rib
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!