Examination of needle surface corrosion in electroacupuncture.

Acupunct Med

Centre for Innovative Structures and Materials, School of Engineering, RMIT University, VIC 3083, Australia.

Published: December 2018

Background: Electroacupuncture (EA) is a modern form of acupuncture therapy where stainless steel acupuncture needles are used as percutaneous electrodes to apply electrical stimulation. The concern about electrolytic corrosion of needles during EA has not been conclusively addressed.

Aim: To examine whether corrosion of stainless steel acupuncture needles occurs after EA to establish the safety profile of this therapy.

Methods: The study comprised four EA sessions on healthy participants mimicking a common clinical practice, with needle surface examinations conducted immediately after each session. Used acupuncture needles that did not undergo electrical stimulation and unused needles taken from the original package were also examined as control comparisons. Two commonly used types of single-use, silicone-coated, stainless steel needles were selected for the experiment. The ES-160 digital acupunctoscope (a charge-balanced electric stimulator) was used to deliver electrical stimulation, and an oscilloscope was used to record the waveforms and electric currents. All needles were sterilised before examination by a scanning electron microscope (SEM), where images of needle tips and shafts were taken for further analysis.

Results And Conclusions: 32 needles were examined under the SEM. As the main findings, the SEM images showed the surface finish, burr attachments and surface characteristics of needle samples. No evidence of electrolytic corrosion was detected on any needle that underwent electrical stimulation for 30 min delivered by a charge-balanced acupunctoscope in healthy participants. The choice of a charge-balanced acupunctoscope is recommended to avoid any potential corrosion of needles in EA clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1136/acupmed-2017-011542DOI Listing

Publication Analysis

Top Keywords

electrical stimulation
16
stainless steel
12
acupuncture needles
12
needles
9
needle surface
8
steel acupuncture
8
electrolytic corrosion
8
corrosion needles
8
healthy participants
8
clinical practice
8

Similar Publications

Technical aspects of neuraxial analgesia during labor and maternity care: an updated overview.

J Anesth Analg Crit Care

January 2025

Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", via Sergio Pansini 5, Naples, 80100, Italy.

Labor analgesia is increasingly widespread throughout the world with a rate ranging from 10 to 60%. The benefits regarding clinical and non-clinical maternal-fetal outcomes are currently discussed in international scientific literature. Even stage of labor needs a different and appropriate approach to control the pain; however, different techniques are reported in literature.

View Article and Find Full Text PDF

Advancing cancer therapy with custom-built alternating electric field devices.

Bioelectron Med

January 2025

School of Pharmacy, Biodiscovery Institute & Boots Science Building, University of Nottingham, Nottingham, NG7 2RD, UK.

Background: In glioblastoma (GBM) therapy research, tumour treating fields by the company Novocure™, have shown promise for increasing patient overall survival. When used with the chemotherapeutic agent temozolomide, they extend median survival by five months. However, there is a space to design alternative systems that will be amenable for wider use in current research.

View Article and Find Full Text PDF

Cancer cells possess distinct bioelectrical properties, yet therapies leveraging these characteristics remain underexplored. Herein, we introduce an innovative nanobioelectronic system combining a piezoelectric barium titanate nanoparticle core with a conducting poly(3,4-ethylenedioxythiophene) shell (BTO@PEDOT NPs), designed to modulate cancer cell bioelectricity through noninvasive, wireless stimulation. Our hypothesis is that acting as nanoantennas, BTO@PEDOT NPs convert mechanical inputs provided by ultrasound (US) into electrical signals, capable of interfering with the bioelectronic circuitry of two human breast cancer cell lines, MCF-7 and MDA-MB-231.

View Article and Find Full Text PDF

Bayesian Optimization Of NeuroStimulation (BOONStim).

Brain Stimul

January 2025

Campbell Family Mental Health Research Institute, Centre for Addiction and Mental Health, Toronto, Ontario, Canada; Department of Psychiatry, University of Toronto, Toronto, Ontario, Canada. Electronic address:

View Article and Find Full Text PDF

An integrated and multifunctional homemade cell sensor platform based on Si-d-CQDs and CRISPR-Cas12a for CD31 detection during endothelial-to-mesenchymal transition.

Talanta

January 2025

Department of Laboratory Medicine, Taihe hospital, Hubei University of Medicine, Shiyan, Hubei, 442000, China; Hubei Key Laboratory of Embryonic Stem Cell research, Hubei University of Medicine, Shiyan, 442000, Hubei, China; Clinical molecular diagnostic center, Taihe hospital, Hubei University of Medicine, Shiyan, Hubei, 442000, China. Electronic address:

Endothelial-to-mesenchymal transition (EndMT) plays a crucial role in the initiation and progression of atherosclerosis and various disease processes. Cluster of differentiation 31 (CD31) is a significant marker in EndMT. Detecting CD31 is essential for early-stage monitoring of EndMT and diagnosing atherosclerosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!