A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Real-Time Recording of Platelet Adhesion to Fibrinogen-Coated Surface under Flow Conditions. | LitMetric

Real-Time Recording of Platelet Adhesion to Fibrinogen-Coated Surface under Flow Conditions.

Bull Exp Biol Med

Laboratory of Stem Cells, Institute of Experimental Cardiology, National Medical Research Center of Cardiology, Ministry of Health of the Russian Federation, Moscow, Russia.

Published: May 2018

We present a testing system allowing real-time recording of the kinetics of platelet adhesion to fibrinogen-coated surface under flow conditions. The system consists of an optical flow chamber, semiconductor laser, two photodetectors, analog-to-digital converter, computer, and peristaltic pump. Platelet adhesion to fibrinogen-coated surface is recorded with two photodetectors and analyzed by the intensity of total internal reflection and scattered laser radiation at the boundary of the blood sample and fibrinogen-coated optical surface. Kinetics of platelet adhesion was studied as a function of shear rate and platelet concentration. The specificity of platelet adhesion with proteins on the surface of the flow chamber was verified by blocking IIb/IIIa glycoprotein complex on platelets with Fab fragments of monoclonal antibodies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10517-018-4119-5DOI Listing

Publication Analysis

Top Keywords

platelet adhesion
20
adhesion fibrinogen-coated
12
fibrinogen-coated surface
12
surface flow
12
real-time recording
8
flow conditions
8
kinetics platelet
8
flow chamber
8
platelet
6
adhesion
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!