The study monitored occupational dose for 12 interventional cardiologists (first operators) and 10 technicians (second operators), from 10 different Lebanese hospitals performing coronary angiography and precutaneous coronary interventions exclusively on adult patients. Each individual wore dosemeters under and over the lead apron at chest and collar level, respectively, on the wrist and next to the left eye. The total follow-up period for each first/second operator varied between two to six bimonthly monitoring periods. For the first operator, the mean (range) effective, hand and eye lens doses were of 6 (1-41), 112 (10-356) and 15 (5-47) μSv/procedure, respectively. These were of 2.3 (0.1-8), 16 (2-109) and 7 (2-14) μSv/procedure for the second operator. Extrapolated annual eye lens doses revealed that both first and second operators may exceed 3/10th of the annual eye lens dose permissible limit thus supporting the need for dedicated eye lens monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncy085DOI Listing

Publication Analysis

Top Keywords

eye lens
16
second operators
12
operators lebanese
8
lens doses
8
annual eye
8
eye
5
occupational doses
4
second
4
doses second
4
operators
4

Similar Publications

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Comparison of two-year myopia control efficacy between spectacle lenses with highly aspherical lenslets and orthokeratology lenses.

Cont Lens Anterior Eye

January 2025

State Key Laboratory of Ophthalmology, Optometry and Vision Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China; National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University, Wenzhou, China. Electronic address:

Purpose: To compare the two-year efficacy of spectacle lenses with highly aspherical lenslets (HAL) and orthokeratology (OK) lenses in managing myopia in children.

Methods: This retrospective study examined medical records from the Affiliated Eye Hospital of Wenzhou Medical University, involving 1683 HAL users and 1192 OK users. Participants were children aged 8-13 with a refractive error of -0.

View Article and Find Full Text PDF

A systematic review of the effectiveness of leaded glasses for ensuring safety among healthcare professionals in fluoroscopy.

J Med Imaging Radiat Sci

January 2025

Instituto Politécnico de Coimbra, ESTESC - Coimbra Health School, Medical Imaging and Radiotherapy, Rua 5 de Outubro, S. Martinho do Bispo, Coimbra 3046-854, Portugal. Electronic address:

Background: Currently, there is an increase in procedures across various clinical specialties involving the use of ionising radiation.

Objective: The primary objective of this systematic review is to analyse and compare the existing literature regarding the effectiveness of leaded glasses for healthcare professionals.

Methods: Comprehensive literature searches were conducted for relevant studies published between 2018 and 2023 using the Scopus, PubMed, and Web of Science databases according to preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology.

View Article and Find Full Text PDF

Ocular Injuries and Intimate Partner Violence: A Review of the Literature.

Clin Ophthalmol

January 2025

Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.

Purpose Of Review: Intimate partner violence (IPV) is a leading cause of death and disability across the world. We sought to investigate the prevalence and clinical presentation of ocular injuries in IPV.

Recent Findings: Literature review revealed 16 published studies that evaluated ocular injuries in IPV, of which the study types included 9 retrospective studies, 2 prospective, 1 review, 1 invited commentary, 2 case reports, and 1 population-based cross-sectional survey.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!